beautypg.com

Pc opera, Installation menu rs232c settings, Pc menu settings – Sanyo CE42SR1 User Manual

Page 9

background image

9

OSD Language, Timer and AV2 settings are the same as in all
input modes (pg 8).
Power save if turned ON will switch the monitor into Powersave
mode after 1 minute if no signal is detected, the LED light will turn a
brighter blue to indicate stand by. The monitor will automatically turn
back on when a signal has been detected (PC input / RGBHV).
Use1 or 2

buttons

to select power save ON or OFF.

Press the menu button twice to initiate Powersave.

This LCD monitor allows you to set up the following:-

SETTING PROCEDURE

1 .

Press and hold the

green button

on the Remote control

handset for 5 seconds.(Installation menu will appear)

2.

Use the 5 or 6

button

to highlight

each option

, use the 1 or

2 button to adjust each option.

On Program

Select ON program using the 5 or 6 button, select the start up
position using the 1 or 2 buttons.
(Off / AV1 / RGB/ AV2/ AV3/ DVI/ PC)
Press the

MENU button

to exit the menu.

Max Volume

Select Max volume using the

5 or 6

button, use the

1 or

2 buttons to set the maximum volume required.

OSD (On screen display)

Select OSD using the 5 or 6 button, select ON / OFF using the
1 or 2 buttons.Selecting OFF will inhibit the OSD. To
re-instate OSD, press and hold the green button on the remote con-
trol to re-enter installation menu and select OSD ON.

Winter mode

This Function can be activated when the LCD monitor is used during
cold temperature conditions, approximately 38˚F/ 4˚C or below to
maintain picture performance.
Using the 5 or 6

button

select winter mode, once highlighted

you can select ON or OFF by pressing the 1 or 2

button

.

IMPORTANT: The AC cord should not be disconnected during the
operation of Winter mode function.
When in winter mode, power consumption is higher than normal
standby consumption. This is entirely due to the operation of heating
circuitry. We strongly recommend to turn off Winter mode when the
ambient temperature is above 38˚F/ 4˚C.

RC Inhibition

You can prevent unwanted remote control operation by selecting RC
Inhibition. When selected an inhibit symbol will appear on screen
when a button is pressed on the remote control.
Select using the 5 or 6

button.

Press the 1 or 2

button

to select On or OFF.
To re-instate RC operation press and hold the green button on the
remote control and select RC inhibition OFF.

Child lock

You can prevent unwanted operation of the LCD monitor via the
buttons on the rear of the monitor.
Select using the 5 or 6

button.

Press the 1

button

to select

On or OFF.

✐ Disconnecting the mains suppy before exiting installation menu

will cancel the following features On program, RC inhibition, Address
and Baud Rate.

This monitor can be controlled via the RS232C connector using a
suitable computer/ control commands.

Serial Interface Specification

Transfer Specification
1. Transmission Speed: initial setting value is 19200.
2. Transmission speed can be changed via the Installation menu
(see below baud rate)

Connection

The Designated RS-232C serial cable must be used for a
connection to a computer and LCD monitor.

The TV command is defined by one command/ one line that starts
with “C” and ends with carriage return. (0x0D)

There are two types of commands:

Functional Execution Command e.g Co5[CR] (table on page 64)
Status Read Commands e.g “CR0 [CR] (see table on page 64)

Setting the monitor address in RS232 mode

To Access Installation mode press the

green button

on the remote

control and hold for 5 seconds. A new screen will appear.

Each monitor can have a specific Address for example 007, which
enables the monitor to be controlled individually and will not affect
other monitors connected to a controlling PC.

Address format command

The addressing format command is used for operating multiple
monitor sets from a single PC via the RS232C command line. If you
set your monitor address to ‘000’, it will never respond to any
addressing command from the PC.
If the address from the PC is ‘FFF’, all monitor sets will execute the
command.
The Address format command is defined by one command, one line
which starts with ‘A’ and ends with carriage return.(0 x0D)
The Monitor starts to decode when it receives a carriage return.
(0x0D)
An address is added at the top of a control command

Example:

Functional execution command:
“A001C05” [CR] means address is 001 and the control command is
C05
Status read command
“A001CR0”[CR] means address is 001 and command is CR0.

The monitor can set its own address in the Installation option menu
(above) The address range is 000 - 999, the default address will be
000
The baud rate indicates the unit for transfer speed of data
from the PC to the monitor sets

PC OPERA

PC OPERA

TION /

TION /

INST

INST

ALLA

ALLA

TION MENU/ RS232C

TION MENU/ RS232C

GB

GB

MENU

ON Program

OFF

Max Volume
OSD

ON/ OFF

Winter mode

ON/ OFF

RC

Inhibition

ON/

OFF

Child

Lock

ON/

OFF

/ AV1-AV3 /RGB/ DVI/ PC

Installation

: Select

: Adjust

: Exit

Address

000-999

Baud

Rate

9600

/

19200

Installation Menu

RS232C settings

ITEM

SPECIFICATION

Synchronous system

Asynchronous

Transmission Speed

9600 / 19200

Data Length

8 bit

Parity

None

Stop Bit

Flow Control

None

1

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9

PC
COM 1

TV CONTROL
PORT

(D-Sub 9 Pin)

(D-Sub 9 Pin)

CD

RXD

TXD

DTR

SG

DSR

RTS

CTS

RING

N.C.

RXD

TXD

N.C

SG

N.C

RTS

CTS

N.C.

MENU

ON Program

OFF

Max Volume
OSD

ON/ OFF

Winter mode

ON/ OFF

RC

Inhibition

ON/

OFF

Child

Lock

ON/

OFF

/ AV1-AV3 /RGB/ DVI/ PC

Installation

: Select

: Adjust

: Exit

Address

000-999

Baud

Rate

9600

/

19200

PC menu settings