beautypg.com

Troubleshooting guide, 18 volts – Shark EP750M User Manual

Page 4

background image

Model EP750M

18 Volts

TM

TROUBLESHOOTING GUIDE

PROBLEM

POSSIBLE REASON

POSSIBLE SOLUTION

HAND VACUUM WILL
NOT OPERATE

1. Batteries

discharged.

2. No power in electrical

outlet supplying
transformer.

3. Unit needs servicing.

1. Charge

unit.

2. Check

fuse

or

breaker.

Replace fuse/reset

breaker.
3. Call 1 800 798-7398

HAND VACUUM WILL
NOT PICK-UP OR
SUCTION POWER IS
WEAK

1. Dust cup container is full.
2. Dust cup filter needs

cleaning.

3. Unit needs recharging.

1. Empty

dust

cup

container

– (see page 4).

2. Remove dust cup filter

and check for object(s) in
air duct and remove.
Clean or replace dust cup
filter. (see page 4).

3. Charge

unit.

DUST ESCAPING
FROM HAND
VACUUM

1. Dust cup container is full.
2. Dust cup filter is not

installed correctly.

3. Puncture/hole in dust cup

filter.

1. Empty

dust

cup

container.

2. Review dust cup filter

installation instructions.
(see page 4)

3. Replace dust cup filter.

(see page 4)

HAND VACUUM
BRUSHES WILL
NOT PICK-UP

1. Extension

tubes

clogged.

2. Dust cup container is full.

1. Remove tube and/or

bushes. Remove
obstruction from tube or
brushes.

2. Empty and clean dust cup

container.

8. Convertible

Brush

9. Motorized Brush with Cord Storage

Compartment

10. Charging Adapter
11. Crevice Tool
12. Recharging Stand
13. Charging Jack
14. Cord Storage Compartment

1. Dust Cup (Container)
2. Dust Cup Release Button
3. On / Off Switch
4. Dust Cup Filter
5. Charging

Light

Indicator

6. Main

Unit

7A. Extension Tubes
7B. Extension Tube With Rubber Seal

NOTE:

Cordless vacuum Model EP750M is shipped with the
batteries uncharged. Charging of the unit for 20
hours prior to first use is required.

2