WASHER
NAMEPLATE
LAG SCREW
SECURE FLANGE
TO STUDS WITH
DRYWALL SCREWS
1/2" BEAD OF
CONSTRUCTION
ADHESIVE
AT 1" CENTERS
CONSTRUCTION
ADHESIVE NEEDS
TO BOND STUDS
TO STIFFENERS
STUD
BACK STIFFENER
STEP 6. SHELF WALL INSTALLATION
CAULKING
ACCESSORY
BRACKET
FRONT NOTCH
CAULKING
A. Attach the accessory brackets to the shelf wall.
B. Temporarily place shelf wall in position, resting shelf
wall on the base. Make certain wall and base are in line
at front notch.
C. Apply a 1/4" bead of sealant to each vertical edge and
around each pin of the body spray wall. Apply a 1/4"
bead of sealant to the shower base edge where the
shelf wall will rest.
D. Place a 1/4" to 1/2" bead of construction adhesive at
each stud where the back surface of the panel stiffen-
ers will make contact.
E. Place the shelf wall in position on the pins of the body
spray wall and against the side stud wall. Secure the
top flange to the stud wall using #6 drywall screws.
The shelf wall must remain seated flush on the shower
base to ensure a matching joint to the corner walls.
Shim top as required to keep the panel square and
perpendicular. Secure the front flange to the side stud
wall using #6 drywall screws. Shim between the flange
and studs as required to maintain plumb walls.
F. Clean off excess sealant.