Warning, Important, Choice of electrical connections – John Lewis JLBIDOS906 User Manual
Page 6: Do not lift the appliance by the handles

6
•
The appliance socket switch should be outside the
cabinet but within 2m of the appliance to make it
accessible to switch off the appliance in case of an
emergency.
•
To protect the hands, wear gloves when lifting the
oven into its housing.
Warning
Do not lift the appliance by the handles.
Important
House circuit
Earth leakage and continuity tests must be carried out before
the appliance is connected to the mains supply and re-checked
after fitting.
Connection
via
Min. size
Cable/flex
Cable/flex
type
Fuse
Cooker
Control
Circuit
6mm
2
PVC/PVC
twin and
earth
35 A (min)
Choice of electrical
connections
•
There are three possible ways to connect your
appliance. In each case the appliance should be
operated using at least 6mm
2
twin core and earth PVC
insulated. Please choose from the most appropriate
after reading the different methods: -
a)
By connecting the appliance to a cooker point (having a
double pole isolating switch with at least 3mm contact
separation in all poles and neutral) and protected with
a fuse or miniature circuit breaker at your mains fuse
box.
Important
Subject to Regional Electricity Companies regulations if you
wish to connect the oven and hob to the power supply you
may use one of the following two methods: -
b)
By connecting the appliance together with a hob
directly to a cooker point(s). Having a double pole
isolating switch with at least 3mm contact separation in
all poles and neutral.
c)
If you wish to connect an oven and a hob to a cooker
point you can by connecting the oven and hob
separately to the cooker point. Oven and hob units
should be separately connected to a cooker point.
Important
It is good practice to:
•
Fit an Earth Leakage Circuit Breaker to your house
wiring.
•
Wire your appliance to the latest IEE regulations.
To remove the mains terminal
cover
•
From the rear of the appliance, remove mains input
terminal cover to gain access to terminal block.
•
First remove retaining screw with a pozidrive
screwdriver.
•
Prise cover loose using screwdriver in position (1) then
lever off with screwdriver in position (2) at either side.
•
Lift cover and remove screw from cable clamp.