Balboa series sub10 – JBL Balboa SUB10 User Manual
Page 5
Parameter
Specification
Unit
QA Test Limits
Conditions
Notes
ATO Turn-on time
< 1
Sec
Functional
Amp connected and AC on, then input
signal applied
Auto Mute/ Turn-OFF Time
10
minutes
Functional
T before muting, after signal is removed
Auto turn of time (T) must be 5 > T <15
Power on Delay time
3
sec.
Functional
AC Power Applied
Transients/Pops
ATO Transient
5
mV-peak
10
@ Speaker Outputs
Turn-on Transient
50
mV-peak
100
@ Speaker Outputs
AC Line cycled from OFF to ON
Turn-off Transient
50
mV-peak
100
@ Speaker Outputs
AC Line cycled from ON to OFF
Efficiency
Stand-by Input Power
13
Watts
14
@ nom. line voltage Unit active, no
signal applied (Green LED)
Maximum allowable input power under
nominal Input voltage and frequency, HOT
or COLD operation.
Power Cons/Amps.@rated
power 120V Model
192 / 1.89
Watts/Amps
208 / 2.00
@ 120V-60 Hz (Nom.line voltage)
100 Watts @ 4 Ohms nominal line voltage
Power Cons/Amps.@rated
power230V Model
208 / 1.1
Watts/Amps
210 / 1.2
@ 230V-50 Hz (Nom.line voltage)
100 Watts @ 4 Ohms nominal line voltage
Protection
Short Circuit Protection
YES
--
Functional
Direct short at output
Thermal Protection
65 deg. C
--
Functional
@1/8 max unclipped Power
Temperature rise should not exceed 35K
rise
DC Offset Protection
YES
--
Functional
DC present at Speaker Out leads
Relay or crowbar (for driver/fire protection)
Line Fuse Rating
120VAC
2.5
Amps
Type-T or Slo Blo
External fuse with UL/SEMKO rated holder
230VAC
1.25
Amps
Type-T or Slo Blo
External fuse with UL/SEMKO rated holder
BALBOA series SUB10
4