beautypg.com

Balboa series sub10 – JBL Balboa SUB10 User Manual

Page 5

background image

Parameter

Specification

Unit

QA Test Limits

Conditions

Notes

ATO Turn-on time

< 1

Sec

Functional

Amp connected and AC on, then input
signal applied

Auto Mute/ Turn-OFF Time

10

minutes

Functional

T before muting, after signal is removed

Auto turn of time (T) must be 5 > T <15

Power on Delay time

3

sec.

Functional

AC Power Applied

Transients/Pops
ATO Transient

5

mV-peak

10

@ Speaker Outputs

Turn-on Transient

50

mV-peak

100

@ Speaker Outputs

AC Line cycled from OFF to ON

Turn-off Transient

50

mV-peak

100

@ Speaker Outputs

AC Line cycled from ON to OFF

Efficiency

Stand-by Input Power

13

Watts

14

@ nom. line voltage Unit active, no
signal applied (Green LED)

Maximum allowable input power under
nominal Input voltage and frequency, HOT
or COLD operation.

Power Cons/Amps.@rated
power 120V Model

192 / 1.89

Watts/Amps

208 / 2.00

@ 120V-60 Hz (Nom.line voltage)

100 Watts @ 4 Ohms nominal line voltage

Power Cons/Amps.@rated
power230V Model

208 / 1.1

Watts/Amps

210 / 1.2

@ 230V-50 Hz (Nom.line voltage)

100 Watts @ 4 Ohms nominal line voltage

Protection
Short Circuit Protection

YES

--

Functional

Direct short at output

Thermal Protection

65 deg. C

--

Functional

@1/8 max unclipped Power

Temperature rise should not exceed 35K
rise

DC Offset Protection

YES

--

Functional

DC present at Speaker Out leads

Relay or crowbar (for driver/fire protection)

Line Fuse Rating

120VAC

2.5

Amps

Type-T or Slo Blo

External fuse with UL/SEMKO rated holder

230VAC

1.25

Amps

Type-T or Slo Blo

External fuse with UL/SEMKO rated holder

BALBOA series SUB10

4