Page 32: 1 standard filtration/heating modes for models, Without circulation pump option (all models), 2 standard filtration/heating modes for models, J-200

background image

J-200

it. For optimum filtration benefits, always leave this valve in position A

when the spa is covered and select positions B or C for maximum jet per-

formance during spa use.

10.7 air Controls

Certain jet systems have their own air control. Each control

introduces air into the water lines that supply that specific jet

group. Simply turn the air control of choice counterclockwise

to open or clockwise to close. To minimize heat loss, all air controls

should be closed when the spa is not in use.

10.8 optional audio system (J-230 to J-280)

Spas equipped with the optional Jacuzzi audio system

offer enhanced enjoyment. These models include

an integrated AM/FM/CD receiver with high-quality marine speakers for

unsurpassed sound quality and long-life.

11.0 automatic Filtration Cycles

The control system activates a programmable “Standard” or “Economy”

filtration cycle to remove debris from your spa. These cycles use the low

speed jets pump 1 and filter cartridge to quickly clear “skim” the water

of debris and minimize their “bathtub ring” affect while the spa is in use

or during a programmed filter cycle. Models equipped with the optional

24-hour circulation pump offer the added benefit of 24-hour filtration for

pennies a day! The circulation pump is not programmable. Apart from their

filtration benefit, each filtration mode also effects the operation of the spa

heater. Refer to Sections 11.1 and 11.2 for details.

11.1

standard Filtration/heating Modes For models without

Circulation pump option (all models)

Standard filtration/heating modes (F1-F3) are typically selected by

customers in cold climates where heat up times are extended due to lower

ambient temperatures. In either of these modes, the water temperature is

regulated by the set temperature, low-speed jets pump 1 and heater which

turns on as needed. After the programmed set temperature is reached, the

heater and low speed pump turn off, only to turn back on during a heat call

or during the next programmed filtration/heating cycle.
11.2

standard Filtration/heating Modes For models with

Circulation Pump option (J-230, J-270 and J-280 only)

Standard filtration/heating modes (F0-F3) are typically selected by

customers in cold climates where heat up times are extended due

to lower ambient temperatures. In either of these modes, the water

temperature is regulated by the set temperature, 24-hour circulation

pump and heater which turns on as needed. After the programmed set

temperature is reached, the heater turns off and the circulation pump

continues to operate 24-hours to filter and clean your spa.