English

Electrical Connections

Pump and Motor

On the following corner units (Capella 55 with integral

skirt, Capella 60 with integral skirt and Tara with

integral skirt), a junction box has been provided. To

access, remove skirt access panel. See top views in

Rough-In section for location.

A dedicated and GFCI protected circuit is required for

pump/motor and is to be installed in the junction box.

The junction box is to be hard wired. The motor is

grounded to the junction box at the factory.

J-Box (supplied)

Bonding to

Motor/Pump

Power Cord to Motor

Capella 55 with skirt, Capella 60 with skirt, Tara with skirt -

Junction Box

Reset

Test

Figure 6

Risk of electric shock. Connect only to a dedicated circuit protected by a GFCI.

When using electrical products, basic precautions should always be followed:

Always follow local building and electrical codes.

Grounding is required. The unit should be installed and grounded by a qualified electrician.

A separate, dedicated 120VAC, 15 Amp GFCI circuit is required for the pump/motor.

Risk of component overheat. Do not use electric extension cord to power this unit.

Operating the motor/pump without enough water in the bathtub can cause leaking and permanent damage.

Electrical outlets must be mounted 4˝ (101mm) above

the floor line, or in accordance with local building and

electrical codes.

-

The pump/motor requires a dedicated 120 VAC, 15

AMP GFCI protected circuit. The electrical outlet is

not provided.

-

Bonding lugs are provided on the heater and motor to

satisfy local electrical codes.

-

At initial start-up, test GFCI units for proper operation.

Follow manufacturer’s instructions on proper use.

If the GFCI units indicate a malfunction, per manufacturer’s instructions, turn OFF power and do not use the

bathtub until the source of the problem has been identified and corrected by a licensed electrician.

The information provided below is applicable to all Jacuzzi

Luxury Bath units.

Pump/Motor

120VAC GFCI Protected,

Dedicated Circuit

(Not Supplied)

Pump/Motor

Pump/Motor (Corner Units)

120V GFCI Protected,

Dedicated Circuit (Not Supplied)