Appendix F: Error Messages

and Troubleshooting

Under certain circumstances, the meter display on the speaker will indicate an “error

message.” Following is a list of conditions that cause an error message to be displayed, and

the corrective action required to cancel the error message.

LIST OF ERROR MESSAGES:

Error

Cause

Display Looks Like

Remedy

No Mic Found

Mic is not connected during

RMC calibration

RMC button blinks and the

meter lights sequentially

from right to left

Press RMC to exit

RMC. Connect mic

and press and hold to

calibrate.

Speaker ID Error

Improper DIP switch setting.

Rear panel DIP switch on this

speaker set to all switches off,

or 2 or more speakers have

same ID setting

All front panel buttons

blink and the meter shows

5 segments moving back

and forth on the speaker

showing the error

Correct DIP switch

settings.

Sync Signal Error

No digital signal found or loss

of sync signal when the S/

PDIF or AES/EBU digital input

is selected.

The Input button will blink

and the first meter LED will

flash to show muted state

Confirm digital signal

is connected.

MUTE

A speaker that is muted

indicates mute is active.

Speaker may be muted by

pressing individual or system

Mute button (in LSR4300

Control Center Software), or

activating SOLO on another

speaker.

First meter LED will blink.

No other meter segments

will be active.

Un-mute individual

speaker or system

mute, exit solo on

other speakers.

Reset

Non-standard DIP switch

configuration used to restore

factory settings. This mode

is entered by setting all DIP

switches ON and re-powering

the speaker.

All front panel buttons

and meter flash rapidly to

indicate reset.

Reset DIP switches

so only a single DIP

switch is active on

each speaker and

re-power.

Appendix F: Error Messages and Troubleshooting