4.6

Engineering Test Modes (AT In)

Format modes:

To enable the function

AT In=1

To disable the function

AT In=0

Modem responds with

OK

Read status:

AT In?

Modem responds with

m

where

m=0, not active
m=1, active

Where

n = 2

Output Continuous Preamble (used for
checking transmitter and receiver). The
preamble is transmitted until stopped by the
ATI2=0 or AT I=10 commands, or ending the
command mode. Note: for a G-Max, this test
must not be run for >10 minutes as damage to
the transceiver may occur.

n = 3

Output a series of 49 byte long data packets
with a programmed period between each
packet set with register S162. The message
data sent is: “The quick brown fox jumps over
the lazy dog.” Each line of data is
pre-ceded by “XX “ where XX is a line number
which increments from 00 - 99.

The data is transmitted until stopped by the
ATI3=0 or AT I=10 commands, or ending
command mode.

n = 4

Adds the Output Data quality and Signal level
data to the end of each received data packet.
This is ended by the ATI4=0 or AT I=10
command. The data format is:

R:XX, D:XXX

where XX = 1 - 10 and XXX = 66 - 256 as
defined in paragraphs 5.10 and 5.12
Note: if data is received before the values have
been read then R:XX, D:XXX will be
output.

n = 9

Gives information about the software version
(refer to paragraph 5.7).

n = 10 Turn off test modes