Appendix, Cv-a11 emulating cv-m10 interfacing, Wen out on pin 6 on 6 pin connector – JAI CV-A11 User Manual
Page 23: Cv-a11
CV-A11
10. Appendix
10.1. CV-A11 emulating CV-M10 interfacing
The CV-A11 has a slightly different pin configuration on the 12-pin Hirose connector, compared
to the M-series. This new configuration is compliant to the EIA-J standard. This means, however,
that the CV-A11 is not completely backward compatible with the CV-M10, CV-M40, etc in all
cases (depending on the cable configuration). The table below shows how to change the pin
configuration, by changing internal solder jumpers.
Please note: Only a qualified electronics technician or engineer should make these changes.
Hirose pin #
Function
JP2
JP3
JP5
JP1
JP4
Remarks
9
PCLK output enabled
Short
Note 2
9
No
connection
Open
10
WEN output
Open
Short
10
Connected to ground
Short
Open
11
Ext Trigger input
Open
Short
11
+12V DC in
Short
Open
Note 1: Configuration shown in Bold+Italic is factory default setting
Note 2: The RS-232C command “CW” must be set to CLK
Fig. 28. PK8304 Rear Board of CV-A11
10.2. WEN out on pin 6 on 6 pin connector
JP1 JP2
Instead of EEN output on pin #6 on the 6 pin Hirose
connector, WEN can be output by jumper settings. The 2
jumpers are found on the main board PK8298B, if the
bottom plate is removed.
Signal on pin #6
JP1
JP2
Remark
EEN out
Open Short default
WEN out
Short Open
Bold+Italic is factory default setting
Fig. 29. PK8298A main board.
- 22 -