Jøtul gf 200 dv lillehammer specifications, Gf 200 dv lillehammer options – Jotul GF 200 DV User Manual
Page 4
4
Jøtul GF 200 DV Lillehammer
Specifications
Figure 1. Dimensional Views - GF 200 DV
Lillehammer
GF 200 DV Lillehammer Options
• Fuel Conversion Kit - NG.............................. 155349
• Fuel Conversion Kit - LP ............................... 155350
• High Altitude Conversion Kit - NG ........... 154371
• High Altitude Conversion Kit - LP ............. 154373
• Wall Thermostat ............................................ 750003
• Remote Control .............................................. 129706
• Mobile Home Floor Bracket Kit ................. 154342
Rear Exit
Centerline
18”
460 mm
13”
330 mm
18 1/2”
470 mm
16 1/2”
420
mm
24”
610 mm
22 3/4”
560
mm
Input Rates
Natural Gas
18,000 BTU/hr. maximum input
13,500 BTU/hr. minimum input
Propane
18,000 BTU/hr. maximum input
13,500 BTU/hr. minimum input
Inlet Pressure:
MIN
MAX
Natural Gas: 5.0 WC (1.24 kPa)
7.0 WC (1.74 kPa)
Propane: 11.0 WC (2.73 kPa) 13.5 WC (3.36 kPa)
Manifold Pressure:
MIN
MAX
Natural Gas: 2.2 WC (.54 kPa)
3.5 WC (.87 kPa)
Propane: 6.5 WC (1.61 kPa) 10.0 WC (2.49 kPa)
Efficiency: 82%
Steady State (A.F.U.E.): 73%
Piezo Ignitor / Standing Pilot
The Jøtul GF 200 DV Lillihammer is a Direct Vent
wall furnace designed as a sealed combustion, air
circulating gas appliance for residential applications.
This appliance is approved for installation using 6 5/
8" X 4" vent pipe from the following manufacturers:
Simpson Dura-Vent GS
Security Vent, Ltd.
Amerivent Inc.
The Jøtul Lillehammer gas stove is designed to
burn NATURAL GAS or PROPANE only. It is shipped
from the factory equipped to burn Natural Gas. If use
with Propane is desired, the stove must first be
converted for use with that gas. Use the LP Fuel
Conversion Kit included with this stove See page 15.