beautypg.com

High-pass frequency recommendations – JBL Control 30 User Manual

Page 4

background image

SS Control 30
CRP 5M
07/07

Control 30 Three-Way High Output Indoor/Outdoor Monitor Speaker

Vertical 1/3 Octave Polars

High-Pass Frequency Recommendations

The line-matching transformer in the Control 30 has
been designed to minimize saturation; however, it is rec-
ommended that the system be high-passed to prevent
very low-frequency content from overloading the trans-
former and/or the driving amplifier at high signal levels.
The high-pass requirements vary according to the tap
settings and number of speakers connected in parallel.
The following chart will eliminate risk of saturation,
even at full voltage (70V or 100V) peaks. Reducing the
drive voltage will enable a corresponding reduction of
high-pass frequency (24 dB/octave high-pass slope).

High Pass Recommendations for Control 30

1 or 2 speakers

3 or more speakers

19 Watt Tap

30 Hz

35 Hz

38 Watt Tap

35 Hz

40 Hz

75 Watt Tap

60 Hz

70 Hz

150 Watt Tap

80 Hz

100 Hz

4 Ohm Setting

No High-Pass required

JBL Professional
8500 Balboa Boulevard, P.O. Box 2200
Northridge, California 91329 U.S.A.

© Copyright 2007 JBL Professional

A Harman International Company

74947_JBL_Ctrl30 6/28/07 9:28 AM Page 4