High-pass frequency recommendations – JBL Control 30 User Manual
Page 4
SS Control 30
CRP 5M
07/07
᭤
Control 30 Three-Way High Output Indoor/Outdoor Monitor Speaker
Vertical 1/3 Octave Polars
High-Pass Frequency Recommendations
The line-matching transformer in the Control 30 has
been designed to minimize saturation; however, it is rec-
ommended that the system be high-passed to prevent
very low-frequency content from overloading the trans-
former and/or the driving amplifier at high signal levels.
The high-pass requirements vary according to the tap
settings and number of speakers connected in parallel.
The following chart will eliminate risk of saturation,
even at full voltage (70V or 100V) peaks. Reducing the
drive voltage will enable a corresponding reduction of
high-pass frequency (24 dB/octave high-pass slope).
High Pass Recommendations for Control 30
1 or 2 speakers
3 or more speakers
19 Watt Tap
30 Hz
35 Hz
38 Watt Tap
35 Hz
40 Hz
75 Watt Tap
60 Hz
70 Hz
150 Watt Tap
80 Hz
100 Hz
4 Ohm Setting
No High-Pass required
JBL Professional
8500 Balboa Boulevard, P.O. Box 2200
Northridge, California 91329 U.S.A.
© Copyright 2007 JBL Professional
A Harman International Company
74947_JBL_Ctrl30 6/28/07 9:28 AM Page 4