Burner and nozzle characteristics – Indesit K 647 GS/G User Manual
Page 7
7
V
I
Fig. E
Fig. F
Important: when mounting the grill burner check that there
is a space of at least 4 mm between the security
thermocouple (if installed) and the burner.
4 mm
Important
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
“regulators for channelled gas”.
Burner and nozzle characteristics
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nominal
Reduced
(mm)
(mm)
***
**
(mm)
Fast
(Large)(R)
100
3.00
0.7
41
86
218
214
116
286
Semi Fast
(Medium)(S)
75
1.90
0.4
30
70
138
136
106
181
Auxiliary
(Small)(A)
55
1.00
0.4
30
50
73
71
79
95
Triple Crown
(TC)
130
3.25
1.5
63
91
236
232
133
309
Oven
-
3.02
1.0
49
85
219
216
132
288
Grill
-
2.50
-
-
80
182
179
122
227
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
3
S
S
R
A
TC
A
S
R
K 642 G/G
K 647 GS/G
K 642 GS/G