TECHNICAL DATA

DIMENSIONS
Height

900 - 915mm

Width

1000mm

Depth

600mm (excluding door handles)

GENERAL
Gas connection

Rp

1

/

2

(

1

/

2

” BSP female)

Pressure test point

Hotplate burner injector

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

230/240V a.c. 50Hz.

Total electrical heat input

7.4 kW

HEAT INPUT

HEAT

INPUT

BURNER

INJECTOR

HEAT INPUT

INJECTOR

Cat II

2H3+

G20 at 20 mbar

Cat II

2H3+

G30 at 28 - 30 mbar

G31 at 37 mbar

240V a.c.

2.7 kW

GRILL

2.5 kW

Left OVEN

2.0 kW

Right OVEN

2.7 kW

2.7 kW (195g/hr)

HOTPLATE
outer front left

125

2.0 kW

HOTPLATE
outer rear left

102

1.8 kW (130g/hr)

82

65

1.0 kW

1.0 kW (75g/hr)

HOTPLATE
inner rear left

72

2.0 kW

HOTPLATE
inner front left

102

1.8 kW (130g/hr)

50

65

1.0 kW

1.0 kW (75g/hr)

HOTPLATE outer
rear right

72

2.0 kW

HOTPLATE outer
front right

102

1.8 kW (130g/hr)

50

65

3.0 kW

2.8 kW (205g/hr)

HOTPLATE
inner front right

128

2.0 kW

HOTPLATE
inner rear right

102

1.8 kW (130g/hr)

82

65

17