Burner and nozzle specifications – Indesit IP 751 S C UK User Manual
Page 5
GB
5
Burner and nozzle specifications
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nomin.
Ridot.
(mm)
(mm)
***
**
(mm)
Fast (R)
100
3,00
0,70
39
86
218
214
116
286
Reduced Fast
(RR)
100
2,60
0,70
39
80
189
186
110
248
Semi Fast (S)
75
1,65
0.40
28
64
120
118
96
157
Auxiliary (A)
55
1,00
0,40
28
50
73
71
79
95
Mini WOK (MW)
110
3,50
1,30
57
91
254
250
138
333
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
*
At 15°C and 1013 mbar-dry gas
**
Propane
P.C.S. = 50.37 MJ/kg.
***
Butane
P.C.S. = 49.47 MJ/kg.
Natural
P.C.S. = 37.78 MJ/m
3
A
S
R
S
A
S
MW
S
A
MW
RR
S
S
IP 751 S C UK
IP 640 S UK
IP 641 S C UK
DATA PLATE
Electrical
connections
See data plate
This appliance conforms to the
following European Economic
Community directives:
-2006/95/EEC dated 12/12/06
(Low Voltage) and subsequent
amendments
- 89/336/EEC dated 03/05/89
(Electromagnetic Compatibility)
and subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 90/336/EEC dated 29/06/90
(Gas) and subsequent
amendments.
- 2002/96/EC