STATIC AND STATIC WITH MOTORIZED DAMPERS MODELS

Sloped Drain

Pan

drainage system

Greentek

TM

HRV units are

equipped with an easy-access

sloped drain pan. Excess

condensation that might

accumulate inside the unit migrate to
the centre of the drain pan to be
evacuated.

9.Condensation Drain Line

Insert the threaded drain adapter thru the bottom of the HRV and hand tighten the plastic nut sup-
plied with the drain kit.

Install the condensate line (10 feet included in drain kit). Insert condensate tubing by pushing clear
plastic line over drain adapter. Make condensate trap by looping the clear plastic tubing. This proce-
dure is to avoid foul odor to enter the HRV .

figure 9.1

Hand screw the drain adapter

figure 9.2 Insert condensate line

figure 9.3

Make a loop in
condensate line

figure 9.4

Use a condensate
pump if you don’t
have access to the
floor drain