GB

DATA PLATE

Dimensions

width cm 43.5
height cm 32
depth cm 43,5

Volume

lt. 60

Electrical
connections

voltage: 230-240V ~ 50/60Hz
maximum power absorbed
2250W-2400W

Directive 2002/40/EC on the label
of electric ovens.
Standard EN 50304

ENERGY LABEL

Energy consumption Class
certification Natural convection
heating mode: Convection
mode.

This appliance conforms to the
following European Economic
Community directives:
73/23/EEC of 19/02/73 (Low
Voltage) and subsequent
amendments;
-89/336/EEC of 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments;
93/68/EEC of 22/07/93 and
subsequent amendments.

Electrical connection

! Ovens with a three-pole power supply cable are

designed to operate with alternated current at the

supply frequency and voltage indicated on the data

plate (at the bottom of the oven dashboard). The

earthing conductor of the cable is the yellow-green

conductor.

Two types of connection are provided:

Connection n° 1

Connecting the power supply cable to the mains.

Fit a normalized plug to the cable, which corresponds

to the load indicated on the data plate; if the cooker is

connected directly to the mains, an omnipolar circuit-

breaker with a minimum opening of 3 mm between the

contacts, suitable for the load indicated and

complying with current directives, must be installed

between the appliance and the mains (the earthing

wire must not be interrupted by the circuit-breaker).

The power supply cable must be positioned so that it

does not exceed room temperature by 50°C at any

point of its length. Before making the connection

check that:

• the circuit breakers or fuses of the home system

can support appliance load (see data plate);

• the power supply system has an efficient earthing

connection which complies with the provisions of

current regulations and the law;

• there is easy access to the socket or the omnipolar

circuit-breaker once the cooker has been installed.

! do not use reducers, adapters or shunts as these

could cause heating or burning.

Connection n° 2

Disposing of the plug.

! THIS APPLIANCE MUST BE EARTHED.

Ensure that before disposing of the plug itself, you

make the pins unusable so that it cannot be

accidentally inserted into a socket. Instructions for

connecting cable to an alternative plug:

! the wires in the mains lead are coloured in

accordance with the following code:

Green & Yellow

-Earth

Blue

-Neutral

Brown

-Live

If the colours of the wires in the mains lead do not

correspond with the coloured markings identifying the

terminals in your plug, proceed as follows.

Connect Green & Yellow wire to terminal marked “E”

or 6 or coloured Green or Green & Yellow.

Connect Brown wire to terminal marked “L” or

coloured Red. Connect Blue wire to terminal marked

“N” or coloured Black. If a 13 amp plug (BS 1363) is

used it must be fitted with a 13 amp fuse.

A 15 amp plug must be protected by a 15 amp fuse,

either in the plug or adaptor or at the distribution

board.If you are in any doubt about the electrical

supply to your machine, consult a qualified electrician

before use.

How to connect an alternative plug

The wires in this mains

lead are coloured in

accordance with the

following code:

BLUE “NEUTRAL” (N)

BROWN

“LIVE” (L)

GREEN AND YELLOW

“EARTH” (E)

Disposing of the appliance

When disposing of the appliance please remove the

plug by cutting the mains cable as close as possible

to the plug body and dispose of it as described

above.

! The plug and socket must be easily accessible.

GREEN &
YELLOW

BROWN

BLUE

13 amp fuse

CROSS-BAR
CORD GRIP