beautypg.com

Electrical connection – Indesit KP59MSXG User Manual

Page 11

background image

9

ELECTRICAL CONNECTION

THE APPLIANCE MUST BE EARTHED
The appliance is designed to work with alternating current
at the supply voltage and frequency indicated on the rating
plate (situated on the rear part of the appliance and on the
last page of the instruction booklet). Make sure that the
local supply voltage corresponds to the voltage indicated
on the rating plate.

Connecting the supply cable to the mains electricity
supply
For models supplied without a plug, fit a standard plug,
suitable for the load indicated on the rating plate, onto the
cable and connect it to a suitable socket.
To connect directly to the mains supply, an omnipolar switch
with a contact break of at least 3 mm suitable for the load
and complying with current standards and regulations must
be fitted between the appliance and the mains supply outlet.
The yellow-green earth wire must not be interrupted by the
switch.
The supply cable must be in such a position that no part of
it can reach a temperature of 50 °C above room temperature.
All the appliances should be connected seperately.
Do not use adapters or shunts as they could cause heating
or burning.
Before connecting to the power supply, make sure that:
• the limiter valve and the domestic system can withstand

the load from the appliance (see rating plate);

• the supply system is efficiently earthed according to the

standards and laws in force;

• the socket or omnipolar switch are easily accessible when

the appliance is installed.

FAILURE TO OBSERVE THE ACCIDENT-PREVENTION
REGULATIONS RELIEVES THE MANUFACTURER OF ALL
LIABILITY.

Replacing the cable
Use a rubber cable of the type H05VV-F with a suitable
cross section of 3 x 1.5 mm².
The yellow-green earth wire must be 2 ÷ 3 cm longer than
the other wires.

Adjusting the low flame
• Put the tap to the low flame position (the burner should

be lit);

• Remove the tap knob and turn the adjusting screw,

situated to the side of the tap stem (fig.10) until you
obtain a regular small flame, using a screwdriver
(loosening the screw increases the height of the flame,
tightening decreases it).

N.B. : the adjusting screw must be fully screwed down

for liquid gas.

• Having obtained the low flame setting required and with

the burner lit, abruptly change the position of the knob
several times from minimum to maximum and vice ver-
sa and check that the flame does not go out.

• Refit the tap knobs

fig.10