Ice-o-matic, Cube i ce m ak er, E. d. f. b – Ice-O-Matic ICE0806 User Manual
Page 2: G. h, C. d. a, C. a, Air cooled, Water cooled/remote, Operating requirements, Dimensions
11100 E. 45th Avenue
Denver, CO 80239
Phone:
303. 371.3737
Fax:
303. 371.6296
www.iceomatic.com
Rev:
A-05/08
Ice-O-Matic
™
®
Part:
1010
IC
E0
80
6/0
80
5
C
ube I
ce M
ak
er
Air Cooled
Please note: air-cooled units require 6. (152 mm) clearance for
air intake and exhaust.
Ice maker potable water in, 3/8" FPT.
A.
Ice maker water out, 3/4" FPT.
B.
Hole for electrical connections, 7/8".
C.
Electrical connection junction box.
d.
Air In–
Rear
Standard Side
Discharge
30"
(762mm)
26" (508 mm)
24"
(610mm)
5" (127mm)
Bin Hanger
5" (127mm)
Bin Hanger
.7" (17.8 mm)
2.6"(66.8 mm)
17.7"
(449.6 mm)
20.5"
(520.7 mm)
22.2"
(564 mm)
B.
C.
D.
A.
.62" (16mm)
Air Cooled
Water Cooled/Remote
Ice maker potable water in, 3/8" FPT.
A.
Ice maker water out, 3/4" FPT.
B.
Hole for electrical connections, 7/8".
C.
Condenser water in, 3/8" FPT.
d.
Condenser water out, 1/2" FPT.
E.
Liquid line, 3/8" male quick connect
F.
coupling for precharged line set
(remote only).
Discharge line, 1/2" male quick connect
G.
coupling for precharged line set
(remote only).
Hole for remote electrical connections,
H.
7/8" (remote only).
22.2"
(564 mm)
5" (127mm)
Bin Hanger
5" (127mm)
Bin Hanger
.7"
(17.8 mm)
2.6"
(66.8 mm)
.62" (16mm)
17.7"
(449.6 mm)
20.5"
(520.7 mm)
22.2"
(564 mm)
E.
D.
F.
B.
C.
A.
3.5" (88.9 mm)
G.
H.
3.0" (76.2 mm)
I.
Water Cooled & Remote
Operating Requirements
Minimum
Maximum
60 Hz
50Hz
Ambient Temp. Range Air
50˚F (10˚C)
100˚F (38˚C)
110˚F (43˚C)
Water Temp.
40˚F (4.4˚C)
100˚F (38˚C)
110˚F (43˚C)
Water Pressure
20 PSIG (1.4 BAR)
60 PSIG (4.1 BAR)
Dimensions
All Models
W x D x H (inches)
30 x 24 x 26
W x D x H (mm)
762 x 610 x 508
Specifications
Model Number Cond. Unit
Ice Production
per 24hrs
Water Usage
gallons per 100 lbs of Ice
90°F air/70°F water
kWH Used
per 100 lbs
of ice @
90°F air/
70°F water
Voltage
Characteristics
Min.
Circuit
Ampacity
Fuse
Size
Approx.
BTUs
per hour
70°F air/
50°F water
lbs (kg)
90°F air/
70°F water
lbs (kg)
Potable
Condenser
ICE0806A
Air
957 (435)
698 (317)
21.8
-
5.8
208-230/60/1
13.0
20
14,464
ICE0806R
Remote*
968 (440)
826 (375)
20.0
-
5.3
208-230/60/1
12.3
20
16,371
ICE0806W
Water
955 (434)
855 (389)
24.9
132
4.0
208-230/60/1
9.8
20
14,816
ICE0805A
Air
918 ( 417)
641 (291)
21.0
-
6.0
230/50/1
11.7
16
13,576
ICE0805R
Remote*
962 (437)
790 (359)
20.3
-
4.9
230/50/1
13.1
16
15,031
ICE0805W
Water
947 (430)
853 (388)
25.7
124
4.0
230/50/1
9.2
16
14,810
*Requires Remote VRC 2061 Condenser and precharged line set
NOTES:
Number of Wires:
3 (including ground)
Approx. Shipping Weight lbs (kg):
ICE0806A 220 (100) • ICE0806R 220 (100) • ICE0806W 210 (96) ) • ICE0805A 220 (100) • ICE0805R 220 (100) • ICE0805W 210 (96)
Refrigerant Type:
R404A
IC
E0
80
6/0
80
5
C
ube I
ce M
ak
er
ICE_Cubers.indd 15
5/8/08 11:21:00 AM