5. list of supported commands, Chapter 9 - appendix, Mode 1 and mode 2 common commands – IBM EGX-400 User Manual
Page 143

139
Chapter 9 - Appendix
9-5. List of Supported Commands
Mode 1 and mode 2 common commands
Command
Format
Parameter
Range [Default]
!DW Dwell
!DW t [terminator]
t
Dwell time
0 to 32767 [ms] [0 [ms]]
!MC Motor Control
!MC n [terminator]
n
Motor ON/OFF switching
-32768 to 32767 [motor ON]
!MC [terminator]
!NR Not Ready
!NR [terminator]
None
!PZ Set Z1&Z2
!PZ z1 (,z2) [terminator]
z1
Z1 coordinates
-4250 to 0 [0]
z2
Z2 coordinates
0 to 4250 [0]
!RC Revolution
!RC n [terminator]
n
Spindle motor
0 to 15, 8000 to 30000 [rpm]
revolution speed
[8000 [rpm]]
!VZ Velocity Select
!VZ s [terminator]
s
Feed rate (Z axis)
0 to 50 [mm/sec] [2 [mm/sec]]
Z-axis
!ZM Z-axis Move
!ZM z [terminator]
z
Z coordinate
-4250 to 0
!ZO Set Z0
!ZO z [terminator]
z
Z machine coordinate
-4250 to 0
!ZZ XYZ-axis
!ZZ x1, y1, z1, .....,
xn, yn
XY coordinate
*1
Simultaneous Feed
xn, yn, zn [terminator]
zn
Z coordinate
*1