Intermec EASYCODER 7421 User Manual
Page 74

B-4
The printer returns its highest priority status when it receives a
valid block (
request command
dump command (
printer status response time ranges from 30 ms to 100 ms
depending on the complexity of the received message block. In
the case of a transmission error, the printer responds with a
The table below shows printer status conditions in descending
order of priority:
Printer Status
Character
Buffer already full
GS
Ribbon fault
US
No label stock
EM
Buffer now full
DC3
Printhead hot
SI
Label at strip pin
FS
Skipping
DC1
Printing
DC1
Ready/Online
DC1
Note:
Do not confuse the Buffer now full
XON/XOFF characters
When the printer returns Buffer Now Full (
accepts the currently received message block. At this time, the
printer can accept short messages to allow parsing of immediate
commands such as Reset (
(). However, if the printer responds with a
message block, the buffer is already full and the printer discards
the entire message block. In case of a transmission error, the
printer discards the whole message block and responds with a
Negative Acknowledgment (NAK). You should retransmit the
message block from the host.