Multi-Tech Systems MULTIMODEM MT2834ZDX User Manual
Page 10

Chapter 3 – AT Commands, S-Registers, and Results Codes
Multi-Tech Systems, Inc. MT2834ZDX User's Guide
10
Command:
%DPn Read Line Probe Data
Values:
n = 0 or 1
Default: 0
Description:
%DP0 Do not read and store line probe information from DSP during handshake.
%DP1 Read and store line probe information from DSP during handshake.
Command:
>DTn DTMF Detection
Values:
n = 0 or 1
Default: 0
Description:
>DT0 The modem will not detect DTMF tones.
>DT1 The modem will detect and report DTMF tones when it is off-hook.
Command:
En Echo Command Mode Characters
Values:
n = 0 or 1
Default: 1
Description:
E0 Do not echo keyboard input to the terminal.
E1 Do echo keyboard input to the terminal.
Command:
&En V.42 Error Correction Modes
Values:
n = 0, 1, or 2
Default: 1
Description:
&E0 V.42 non-error correction mode (V.42 disabled).
&E1 V.42 auto-reliable mode.
&E2 V.42 reliable mode (V.42 enabled).
Command:
&En Modem-Initiated Flow Control
Values:
n = 3, 4, or 5
Defaults: 4
Description:
&E3 Flow control disabled.
&E4 CTS/RTS hardware flow control.
&E5 XON/XOFF software flow control.
Command:
&En XON/XOFF Pass-Through
Values:
n = 6 or 7
Defaults: 6
Description:
&E6 Respond to and discard XON/XOFF characters when &E5 is selected.
&E7 Respond to and pass through XON/XOFF characters when &E5 is selected.
Command:
&En Hewlett Packard ENQ/ACK Pacing
Values:
n = 8 or 9
Default: 8
Description:
&E8 Ignore ENQ/ACK pacing characters.
&E9 Respond to ENQ/ACK pacing characters.
Command:
&En Non-Error Correction Mode Flow Control
Values:
n = 10 or 11
Default: 10
Description:
&E10 Disable non-error correction mode flow control.
&E11 Enable non-error correction mode flow control.
Command:
&En Pacing (Computer-Initiated Flow Control)
Values:
n = 12 or 13
Default: 13
Description: &E12
Pacing
disabled.
&E13 Pacing enabled.
Command:
&En Data Compression
Values:
n = 14 or 15
Default: 15
Description:
&E14 Data compression disabled.