beautypg.com

Service procedures, Warning – Master Lock 70000 BTU/Hr User Manual

Page 10

background image

10

101585

SERVICE

PROCEDURES

Upper Shell Removal

1. Remove screws along each

side of heater using 5/16"
nut-driver. These screws
attach upper and lower
shells together.

2. Lift upper shell off.
3. Remove fan guard.

Figure 10 - Fuel Filter Removal, 70,000 BTU/Hr Model

Fuel Filter

Side Cover

Fuel Line

Fuel Filter

(70,000 BTU/Hr Model)

1. Remove side cover screws

using 5/16" nut-driver.

2. Remove side cover.
3. Pull rubber fuel line off

fuel filter neck.

4. Carefully pry bushing and

fuel filter out of fuel tank.

5. Wash fuel filter with clean

fuel and replace in tank.

6. Attach rubber fuel line to

fuel filter neck.

7. Replace side cover.

Upper
Shell

Fan
Guard

Upper
Shell

Fan
Guard

Figure 8 - Upper Shell Removal, 70,000 BTU/Hr Model

WARNING

Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.

Figure 9 - Upper Shell Removal, 100/150,000 BTU/Hr Models

This manual is related to the following products: