beautypg.com

Milwaukee 6268-21 User Manual

Page 4

background image

6

7

Grounded tools require a three wire ex-
tension cord. Double insulated tools can
use either a two or three wire extension
cord. As the distance from the supply out-
let increases, you must use a heavier
gauge extension cord. Using extension
cords with inadequately sized wire causes
a serious drop in voltage, resulting in loss
of power and possible tool damage. Refer
to the table shown to determine the re-
quired minimum wire size.

The smaller the gauge number of the wire,
the greater the capacity of the cord. For
example, a 14 gauge cord can carry a
higher current than a 16 gauge cord. When
using more than one extension cord to make
up the total length, be sure each cord con-
tains at least the minimum wire size re-
quired. If you are using one extension cord
for more than one tool, add the nameplate
amperes and use the sum to determine the
required minimum wire size.

Guidelines for Using Extension Cords

If you are using an extension cord out-
doors, be sure it is marked with the
suffix “W-A” (“W” in Canada) to indi-
cate that it is acceptable for outdoor
use.

Be sure your extension cord is prop-
erly wired and in good electrical
condition. Always replace a damaged
extension cord or have it repaired by a
qualified person before using it.

Protect your extension cords from
sharp objects, excessive heat and
damp or wet areas.

READ AND SAVE ALL INSTRUCTIONS FOR FUTURE USE.

Recommended Minimum Wire

Gauge for Extension Cords*

Extension Cord Length

* Based on limiting the line voltage drop to
five volts at 150% of the rated amperes.

Nameplate

A m p e r e s

0 - 2.0

2.1 - 3.4
3.5 - 5.0
5.1 - 7.0

7.1 - 12.0

12.1 - 16.0
16.1 - 20.0

25'

18
18
18
18
16
14
12

75'

18
18
16
14
12
10

100'

18
16
14
12
10

150'

16
14
12
12

50'

18
18
18
16
14
12
10

EXTENSION CORDS

The grounding prong in the plug is con-
nected through the green wire inside the
cord to the grounding system in the tool.
The green wire in the cord must be the
only wire connected to the tool's ground-
ing system and must never be attached to
an electrically “live” terminal.

Your tool must be plugged into an appro-
priate outlet, properly installed and
grounded in accordance with all codes and
ordinances. The plug and outlet should look
like those in Figure A.

Double Insulated Tools:
Tools with Two Prong Plugs

Tools marked “Double Insulated” do not re-
quire grounding. They have a special
double insulation system which satisfies
OSHA requirements and complies with the
applicable standards of Underwriters Labo-
ratories, Inc., the Canadian Standard As-
sociation and the National Electrical Code.
Double Insulated tools may be used in ei-
ther of the 120 volt outlets shown in
Figures B and C.

Grounded Tools:
Tools with Three Prong Plugs

Tools marked “Grounding Required” have
a three wire cord and three prong ground-
ing plug. The plug must be connected to a
properly grounded outlet (See Figure A). If
the tool should electrically malfunction or
break down, grounding provides a low re-
sistance path to carry electricity away from
the user, reducing the risk of electric shock.

Fig. B

Fig. C

Fig. A

Improperly connecting the
grounding wire can result in the
risk of electric shock. Check with
a qualified electrician if you are in
doubt as to whether the outlet is
properly grounded. Do not modify
the plug provided with the tool.
Never remove the grounding
prong from the plug. Do not use
the tool if the cord or plug is dam-
aged. If damaged, have it repaired
by a MILWAUKEE
service facility
before use. If the plug will not fit
the outlet, have a proper outlet
installed by a qualified electrician.

GROUNDING

WARNING!