Weld process board pc4 diagnostic led’s, Diagnostic led’s on process board pc4, 2. weld process board pc4 diagnostic led’s – Miller Electric Axcess 300 User Manual
Page 40: 3. diagnostic led’s on process board pc4

OM-230 032 Page 34
1
Weld Process Board PC4
Diagnostic LED’s are visible inside unit,
located on PC4 mounted on the top tray.
Refer to Section 9-3 for information on
diagnostic LED’s.
Reinstall cover after checking diagnostic
LED’s.
216 956-A / Ref. 803 670-A
9-2.
Weld Process Board PC4 Diagnostic LED’s
1
LED2
LED1
LED4
LED3
9-3.
Diagnostic LED’s On Process Board PC4
LED
Status
Diagnosis
1
On
Indicates −25 volts dc is present on process board PC4
Off
Indicates −25 volts dc is not present on process board PC4
2
On
Indicates +25 volts dc is present on process board PC4
Off
Indicates +25 volts dc is not present on process board PC4
3,4
On
See Network Status Table in Section 9-4
Off
See Network Status Table in Section 9-4
See also other documents in the category Miller Electric Tools:
- OM-2241 (32 pages)
- ICE-27C (36 pages)
- Arc Welding Power Source (4 pages)
- INVISION 456 CC (44 pages)
- Welder (132 pages)
- SS-75D12 (44 pages)
- Load Bank LBP-350 (2 pages)
- OM-193 084E (36 pages)
- 750MPa (2 pages)
- APT-1000 (20 pages)
- OM-220 390F (48 pages)
- 271 (48 pages)
- Welding (32 pages)
- DC (72 pages)
- OM-129 (70 pages)
- XLi (24 pages)
- S-64 (36 pages)
- ICE-27T (36 pages)
- PipePro 304 (76 pages)
- AA40GBU (28 pages)
- D-64 (40 pages)
- Auto Arc XLT 165 (48 pages)
- 185 DX (56 pages)
- S-32S (4 pages)
- Big 40 DC/TIG 55500 A (8 pages)
- Big Blue 600D (60 pages)
- Millermatic 140 (60 pages)
- pmn (36 pages)
- LMSW Series (2 pages)
- 1250 (46 pages)
- Trailblazer Pro 350 D (8 pages)
- TS (76 pages)
- S-22P12 (28 pages)
- 602 (40 pages)
- MOG-400 (40 pages)
- WC-24 (20 pages)
- Big Blue 502P (64 pages)
- Dimension 1000 (44 pages)
- DS-74DX12 (52 pages)
- 350 VS (36 pages)
- 24A (32 pages)
- GA-16C (12 pages)
- Big Blue 502D (116 pages)
- OM-229 038D (36 pages)