beautypg.com

M400bfc balanced flue heat-circulating fireplace, Common materials and factors, Glass door operation – Monessen Hearth M400BFC User Manual

Page 17: Example for common brick

background image

17

M400BFC Balanced Flue Heat-Circulating Fireplace

87D1505

WARNING: Hearth extension must be installed in
accordance with Figure 23 and must not cover the
bottom front opening of the circulating model.
Alternate noncombustible materials may be used pro-
viding the (total) thermal resistance (Rt value) of the al-
ternate material employed is greater than or equal to R
= 1.09 Thermal resistance (R) or thermal conductivity
(K), may be obtained from manufacturer of the material.
Factors are related by the formula K = 1/R. (Fig. 24)
T = given thickness
R = thermal resistance for a given thickness (T)
K = thermal conductivity
Noncombustible material with a lower R value may
be used, provided thickness of material is sufficiently
greater to maintain an equivalent (total) thermal resis-
tance (Rt).

COMMON MATERIALS AND FACTORS

MATERIAL

K*

R

MINIMUM

THICKNESS

EH2416

Common Brick

0.458

5.0

1.09 0.50 in.**

0.10 5.46 in.**

(MHSC)

R Value is for 1/2 inch.

* Units of K = BTU/SQ FT/HR/˚F/IN

** Thickness of Listed Material

FP533ADD

Addendum

6/1/99 djt

8/4/99 changed .2 to .1

one inch to 1/2 inch djt

FP533ADD

Fig. 22 Hearth extension material factors.

Example of Determining Hearth Extension
Equivalents

To determine the thickness required for any new mate-
rial:

NEW

K of new material (per inch)

thickness

required

= --------------------------------------- X of listed

thickness

K of listed material (per inch)

material

Example for Common Brick

T (new) = 5.0/0.458 x 0.50 in. = 5.46 in. (new required
thickness).

FP550

BR/BC - SEALING

DETAILS

9/29/97

Wall Covering

Noncombustible

Decorative Fac-

ing

Seal all cracks

between fireplace

surround and wall

materials with non-

combustible material.

Noncombus-

tible Decorative

Covering

Hearth Exten-

sion Insulation

2 x 4” Header

- Do not notch at

standoffs

Seal crack between

fireplace and hearth

extension with noncom-

bustible material

Safety Strips -

Must be overlapped 1/2”

minimum

Side View

FP550

Fig. 23 Sealing gaps.

KT108b
BFC
Correct door position
8/23/00 djt

Correct

Wrong

Fig. 28 Correct door position.

KT108b

Glass Door Operation

The M400BFC is intended for use only with the doors
fully closed. (Fig. 28)