NOTE: The service indicator must be green before proceeding.

4) Your device is ready to be repacked (see Repacking p. 13).

Usage Below Freezing

When the temperature is below freezing, the Inflatable PFD should
be worn partially inflated because a fully discharged cylinder may not
quickly or adequately inflate your Inflatable PFD. Under these conditions
use the oral inflator to adequately top-up the PFD, after CO2 inflation.
WARNING: CO2 inflation could over-pressurize and damage your

Inflatable PFD if already fully inflated.

Re-arming Your PFD (MD2085)

NOTE: A re-arm kit (MA7203) is required for this procedure.

IMPORTANT: Follow instructions in the exact sequence below.

1) Open inflator cover flap so that manual inflator is exposed (Fig. 7).
2) Remove the cylinder/bayonet assembly by rotating counterclockwise

and then pull out. Discard the used cylinder/bayonet assembly.

3) Check the new cylinder/bayonet assembly to ensure the o-ring is in

place and the sensor ring is attached (Fig. 10). Ensure that the CO2

cylinder has not been pierced (Fig. 10).

Inflatable PFD Owner’s Manual

8

Dust cap
position for
deflation

Dust cap
in stowed
position

Oral Inflator

FIGURE 6

Cap In

Deflate

Position

FIGURE 5