METRObility Optical Systems R200 User Manual
Page 8
8
Installation Guide
• Turn ON the DC voltage source.
• Verify proper power connection and operation by observing that the
power (PWR) LED on the line card is lit.
AC Power Supply Connections
For AC connections, follow these guidelines:
• Insert the power cord to the receptacle on the R200-AC.
• Connect the power cord plug to the AC power source.
• Verify proper power connection and operation by observing that the
power (PWR) LED on the line card is lit.
DC plug connector
wire leads
48 VDC 1 AMP
DISCONNECT ALL POWER SOURCES BEFORE SERVICING
+
+
• Insert the plug connector into the header on the R200 and tighten the
two screws.