SPECIFICATIONS

Model

MM-AVR 600

MM-AVR 800

MM-AVR 1200

Capacity

600VA/300W

800VA/480W

1200VA/600W

Phase

Single phase

Voltage Range

95V-145V ±3V

Input

Frequency

60HZ ±5HZ

Voltage

(battery mode)

120V ±10%

Waveform

AC mode - follow utility

Battery mode - Step Sine Wave

Frequency

AC mode - follow utility, Battery mode - 60Hz ±5Hz

Frequency

<0.5HZ (battery operation)

Output

Transfer Time

Typical 4ms, max 10ms

Surge Protection

320 Joules

Input Protection

Compliance with IEEE 587

Protection

Short Circuit

Fuse

Type

12V Sealed non-spillable lead acid, maintenance free

Recharge

After full discharge, 8 hours to 90% capacity

Backup Time

(full load)

≥3 min

Charge Current

350mA

~1A

Battery

Battery

Configuration

1x12V/7AH

1x12V/9AH

2x12V/7AH

AC Mode

Green and Orange LED on, Red LED off,

No Alarm

Charging Battery

Orange LED on

Battery Mode

Green and Orange LED off, Red LED flash,

Alarm slow beep

Indication

Battery Low

Green and Orange LED off, Red LED flash,

Alarm fast beep

Audible Noise

at 1 m (3 ft)

<45dB

Temperature

0 to 40

°C (+32 to +104°F)

Environment

Humidity

0% - 90% Non- Condensing