English – Metabo Power 260 User Manual
Page 10
10
ENGLISH
After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts remain on or in the device.
Compressor does not run:
• No mains voltage.
− Check cables, plug, outlet and
mains fuse.
• Mains voltage too low.
− Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
device.
• Compressor was stopped by
unplugging.
− Switch compressor OFF at the
On/Off switch, then ON again.
• Motor has overheated, caused by
insufficient cooling (cooling fins
covered).
− Remove cause for overheating
and allow to cool down for
approx. 10 minutes, then start
again.
Compressor runs but does not build
up sufficient pressure.
• Condensate drain of pressure ves-
sel leaky.
− Check gasket of drain screw(s);
replace if necessary.
− Tighten drain screw(s) fingertight.
• Check valve leaky.
− Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
• Pressure regulator not opened wide
enough.
− Open pressure regulator more.
• Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
The device's packaging can be 100 %
recycled.
Worn out devices and accessories con-
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled.
These instructions are printed on chlo-
rine-free bleached paper.
7.
Repairs
8.
Environmental Protection
9.
Technical Specifications
Suction capacity
l/min
235
Free air delivery (volume flow rate)
l/min
110
Filling rate
l/min
120
Max. working pressure
bar
8
Pressure vessel volume
l
4
Pump model
F 245
No. of cylinders
1
Motor speed
min
-1
2850
Motor capacity
kW
1.5
Supply voltage (50 Hz)
V
230
Rated current
A
6.8
Fuse protection min.
A
10 (time-lag)
Degree of protection
IP 20
Maximum overall length when using extension cables with:
– 3 x 1.0 mm
2
lead cross-section
– 3 x 1.5 mm
2
lead cross-section
– 3 x 2.5 mm
2
lead cross-section
m
m
m
10
25
25
Dimensions: length x width x height
mm
600 x 310 x 405
Weight kg
18
Sound pressure level at 1 m max.
dB (A)
87 ± 3