beautypg.com

English – Metabo Power 260 User Manual

Page 10

background image

10

ENGLISH

After all servicing:

Check to see that all safety

devices are operational.

Make sure that no tools or other

parts remain on or in the device.

Compressor does not run:

• No mains voltage.

− Check cables, plug, outlet and

mains fuse.

• Mains voltage too low.

− Use only extension cables with

sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
device.

• Compressor was stopped by

unplugging.
− Switch compressor OFF at the

On/Off switch, then ON again.

• Motor has overheated, caused by

insufficient cooling (cooling fins
covered).

− Remove cause for overheating

and allow to cool down for
approx. 10 minutes, then start
again.

Compressor runs but does not build
up sufficient pressure.

• Condensate drain of pressure ves-

sel leaky.
− Check gasket of drain screw(s);

replace if necessary.

− Tighten drain screw(s) fingertight.

• Check valve leaky.

− Have check valve serviced by

qualified service centre.

Air tool is not supplied with sufficient
pressure.

• Pressure regulator not opened wide

enough.
− Open pressure regulator more.

• Hose connection between compres-

sor and air tool leaky.
− Check air hoses, replace defec-

tive parts if necessary.

A

Danger!
Repairs to power tools must be

carried out by qualified electricians
only!

Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.

Please attach a description of the fault to
the power tool.

The device's packaging can be 100 %
recycled.

Worn out devices and accessories con-
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled.

These instructions are printed on chlo-
rine-free bleached paper.

7.

Repairs

8.

Environmental Protection

9.

Technical Specifications

Suction capacity

l/min

235

Free air delivery (volume flow rate)

l/min

110

Filling rate

l/min

120

Max. working pressure

bar

8

Pressure vessel volume

l

4

Pump model

F 245

No. of cylinders

1

Motor speed

min

-1

2850

Motor capacity

kW

1.5

Supply voltage (50 Hz)

V

230

Rated current

A

6.8

Fuse protection min.

A

10 (time-lag)

Degree of protection

IP 20

Maximum overall length when using extension cables with:
– 3 x 1.0 mm

2

lead cross-section

– 3 x 1.5 mm

2

lead cross-section

– 3 x 2.5 mm

2

lead cross-section

m
m
m

10
25
25

Dimensions: length x width x height

mm

600 x 310 x 405

Weight kg

18

Sound pressure level at 1 m max.

dB (A)

87 ± 3