OM-4423 Page 28

6-5. Remote Voltage/Amperage Control

1

Remote 14 Receptacle RC14

Connect optional remote control to RC14 (see

Section 5-9).

.

When a remote control is connected to the
Remote receptacle, the Auto Sense Re-

mote feature automatically switches volt-

age/amperage control to the remote con-

trol. When a device is connected to the Re-

mote receptacle, remote voltage/amper-

age control is always available regardless

of the position of the Process/Contactor

switch.

0774 / Ref. 217 358-B / Ref. 803 576−C

Adjust Optional Remote Control

Set V/A Control

To Desired Maximum

Weld Output Using Weld

Meters

Set TIG or STICK Process

Adjust Optional Remote

Control To Desired Weld

Output

In Example:

Process = Remote Stick

Min = 20 A DC

Max = 205 A DC

Max (205 A DC)

Min (20 A DC)

Connect Remote

Control To Remote

Receptacle RC14

Connect Remote

Control To Remote

Receptacle RC14

Set WIRE Process

1

Adjust Optional Remote

Control to 100%

Weld meters will always

show the combined main and

remote control setting and

machine welds at nominal

output settings of the meter.

Weld meters show preset