Performance data – hoods for propeller models, Heater parts from acf greenhouses – Modine Manufacturing GAS-FIRED HEATERS BD User Manual
Page 16

PD 50
PD 75
PD 100
PD 125
PD 150
PD 175
PD 200
PD 250
PD 300
PD 350
PD 400
Models
S
S
S
S
S
S
S
S
S
S
S
8'
10
23
30
34
38
42
36
54
62
58
56
10'
11
20
27
30
34
37
32
48
56
52
50
12'
12
19
24
27
31
34
29
44
51
47
46
14'
17
23
25
29
32
27
41
47
44
42
16'
16
21
24
27
29
25
38
44
41
39
18'
20
22
25
28
24
36
42
38
37
20'
19
21
24
26
23
34
40
36
35
22'
23
25
22
33
38
35
34
24'
31
36
33
32
26'
30
35
32
31
28'
29
33
31
30
30'
32
30
29
PD 50
PD 75
PD 100
PD 125
PD 150
PD 175
PD 200
PD 250
PD 300
PD 350
PD 400
Models
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
8'
0 19 26
0 26 36
0 33 45
0 34 47
0 38 52
0 40 55
0 35 47
0 47 65
0 52 72
0 49 68
0 48 66
10'
0 14 19
0 23 32
0 31 42
0 32 44
0 36 49
0 39 53
0 33 45
0 46 63
0 51 70
0 48 66
0 47 64
12'
0 18 25
0 28 38
0 29 40
0 33 46
0 36 50
0 30 41
0 44 60
0 50 68
0 46 64
0 45 62
14'
0 10 14
0 23 33
0 25 35
0 30 41
0 33 46
0 26 36
0 41 57
0 48 65
0 44 61
0 43 59
16'
0 13 19
0 18 25
0 25 35
0 29 41
0 19 27
0 38 53
0 45 62
0 41 57
0 40 55
18'
0 12 17
0 13 19
0 23 32
0 12 17
0 35 48
0 42 58
0 38 52
0 36 50
20'
0 29 40
0 38 52
0 33 46
0 31 43
22'
0 16 23
0 32 45
0 25 35
0 21 30
24'
0 19 28
0 16 24
0 16 23
PD 50
PD 75
PD 100
PD 125
PD 150
PD 175
PD 200
PD 250
PD 300
PD 350
PD 400
Models
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
X Y Z
8'
8 19 26 11 25 34 14 31 43 15 32 44 16 36 49 18 38 52 15 33 45 21 44 60 24 49 67 22 46 63 22 45 62
10'
6 15 22 9 23 22 13 30 41 14 31 43 15 34 47 17 37 51 14 31 43 20 43 59 23 48 66 21 45 62 21 44 61
12'
4 12 17 7 20 28 11 28 39 12 29 40 14 33 45 15 35 49 12 30 41 19 42 58 21 47 65 20 44 61 19 43 59
14'
5 14 21 10 25 35 10 26 37 12 30 42 14 33 46 11 27 37 17 40 56 20 46 63 19 43 59 18 42 57
16'
5 17 25
7 21 30 10 27 38 12 31 43
8 22 31 16 38 53 19 44 61 17 41 56 16 40 55
18'
6 18 26
6 20 29 9 26 37
6 18 26 14 36 50 17 42 58 15 38 53 15 37 52
20'
12 32 45 15 39 54 13 35 49 13 33 47
22'
8 24 35 13 35 49 10 29 42 8 25 37
24'
8 26 38
8 24 36 8 24 35
Mounting
Height to
Bottom of
Heater
Mounting
Height to
Bottom of
Heater
16
PERFORMANCE DATA – HOODS FOR PROPELLER MODELS
Performance Data — 30°, 60° and 90° Downward Deflector Hoods
OUNTING
HEIGHT
X
Y
Y
Z
Z
X
60 NOZZLE
30 NOZZLE
60
30
30 DOWNTURN NOZZLE
60 DOWNTURN NOZZLE
NOTE:
X = FEED FROM HEATER
TO START OF
FLOOR COVERAGE.
Y = FEET TO END OF
FLOOR COVERAGE.
Z = FEET TO END OF
THROW.
30° HOOD
60° HOOD
THROW-FLOOR COVERAGE
Mounting
Height to
Bottom of
Heater
30° Downward Hood For Propeller Units ➀
➀
Data Based on units fired at full rated input with an entering air temperature of 60°-80°F. Maximum mounting heights higher versus units without outlet devices.
60° Downward Hood For Propeller Units ➀
90° Downward Hood For Propeller Units ➀