Section 3 − introduction, 1. specifications, Section 4 − installation – Miller Electric Axcess User Manual
Page 13: 1. selecting a location
![background image](/manuals/123296/13/background.png)
OM-211 076 Page 9
SECTION 3 − INTRODUCTION
3-1. Specifications
Type of Input
Power
Welding Power
Source Type
Wire Feed Speed Range
Wire Diameter
Range
Welding Circuit
Rating
Overall
Dimensions
Weight
40 Volts DC
10 Amperes
Axcess Series
Standard: 40 To 1400 ipm (1.0
To 35.6 mpm)
.030 To 1/8 in
(0.8 To 3.2 mm)
Max Spool
Weight: 60 lb (27
kg)
100 Volts,
750 Amperes,
100% Duty
Cycle
Length: 27 in (686
mm)
Width: 12-1/2 in
(318 mm)
Height: 14-1/2 in
(368 mm)
46 lb
(20.9 kg)
SECTION 4 − INSTALLATION
4-1. Selecting A Location
loc_2 3/96 - Ref. 803 502-A
Y Do not stack units. Beware of
tipping.
1
Lifting Forks
Use lifting forks to move unit.
Extend forks beyond opposite side
of unit.
2
Hand Cart
Use cart or similar device to move
unit.
3
Rating Label
Use rating label to determine input
power needs.
4
Line Disconnect Device
Locate unit near correct input
power supply.
Movement
2
Location
4
18 in
(460 mm)
18 in
(460 mm)
Y Do not move or operate
unit where it could tip.
Tipping
1
OR
Y Special installation may be required where gasoline or volatile
liquids are present − see NEC Article 511 or CEC Section 20.
3