OPLH-94122B page 3 of 4

8 in.

(203 mm)

6-25/64 in.

(162 mm)

8 in.

(203 mm)

Rear mounting holes
for surface mounting
3/8-16 UNC-2B
7/8 in. (22 mm)
deep, 4 places.

Removable lid
to access adjustable
contact knobs.

6-3/4 in.

(171 mm)

6-3/4 in.

(171 mm)

Mounting Hole
7-35/64 in. (192 mm)
diameter. Not required
for surface mounting.

1/2 NPT
optional
rear or side
conduit

3/8-16 UNC-2B
7/8 in. (22 mm)
deep, 4 places.

Process Connection
1/4 NPT Female

Explosion-proof Enclosure (“EX” Option)

8-7/16 in.

(214 mm)

3-3/8 in.

(86 mm)

7-7/8 in.

(200 mm)

3-15/16 in.

(100 mm)

4-1/32 in.

(102 mm)

Mounting Holes
9/32 in. (7 mm)
diameter 3 places.
Not available on
panel mount
square case.

1/2 NPT
conduit

Process Connection
1/4 NPT male on
bourdon tube models
and 1/4 NPT female
on bellows models.

Surface

NOTE:
Panel mount
square case models
do not include
mounting flange and
include bolt circle
shown in Panel Mount
Enclosure versions
(see below).

120

120

120

5-7/16 in.

(138 mm)

2-57/64 in.

(73 mm)

Mounting Hole
4-3/4 in. (121 mm)
diameter.

Process Connection
1/4 NPT Male.

Panel

1/4 in. (6 mm) dia.
holes (3 places.)
on 5-13/64 in.
(132 mm) b.c.
(bolt circle),120
apart, clocking
as shown

Dimensions

Surface / Panel Mount Enclosure (Square Case)

Panel Mount Enclosure

(Round Case)

Typical Applications

Above Ground Tank

Below Ground Tank

SWICHGAGE

®

Flow regulator
(recommended)

Pressure
regulator

Head
Pressure

Air compressor

Tank

Tank

SWICHGAGE

®

Direct Mount

Remote
SWICHGAGE

®

with Sensing Line
Underground

Direct and Remote Tank

Flow regulator
(recommended)

Pressure
regulator

SWICHGAGE

®

1 foot

Ground surface

Air compressor

Underground tank
(vented)