Section 3 − introduction, 1. specifications, Section 4 − installation – Miller Electric DS-75S16 User Manual
Page 13: 1. installing swivel into pipe post
OM-230 300 Page 9
SECTION 3 − INTRODUCTION
3-1. Specifications
Type of Input
Power
Welding Power
Source Type
Wire Feed Speed
Range
Wire Diameter
Range
Welding Circuit
Rating
Weight
24 Volts AC
Single-Phase
10 Amperes
50/60 Hertz
Constant Voltage (CV)
DC With 14-Pin that provides
voltage and current feedback
Standard: 50 To 1400
ipm (1.3 To 35.6 mpm)
.023 To 5/64 in (0.6
To 2.0 mm)
Max Spool Weight:
60 lb (27 kg)
100 Volts,
750 Amperes, 100%
Duty Cycle
12 ft (3.7 m):
207 lb (94 kg)
16 ft (4.9 m):
280 lb (127 kg)
12 ft (3.7 m) Boom
16 ft (4.9 m) Boom
Maximum Height With 4 ft (1.2 m) Post
17 ft (5.2 m)
21 ft (6.4 m)
Vertical Lift Of Boom
Horizontal to 60
°
Above Horizontal
Horizontal to 60
°
Above Horizontal
If feeder is used with a welding power source that does not provide voltage and
current feedback through the 14-pin control cable, run-in will be disabled. Arc
voltage will not be displayed on feeders equipped with meters.
NOTE
SECTION 4 − INSTALLATION
4-1. Installing Swivel Into Pipe Post
152 268-B
Y Do not remove Safety Collar
until instructed to.
1
Swingpak Base or CBC Cart
2
Pipe Post With Base
3
Steel Bolt
Secure as shown using as a mini-
mum 1/2 in diameter SAE grade 5
steel bolts.
4
Swivel Assembly
Insert into pipe post. Lubricate
swivel.
5
Safety Collar
Tools Needed:
3/4 in
1
2
3
4
5