17

APPENDIXB

ACOUSTICAl
Note:
Recommended maximum operating frequency range. Response depends on loading conditions and room

acoustics.
Operating frequency range

55 Hz – 18 kHz
Note: Recommended maximum operating frequency range. Response depends on loading

conditions and room acoustics.

Frequency response

60 Hz – 16 kHz ±4 dB
Note: Half-space loading measured with 1/3-octave frequency resolution at 4 meters.

Phase response

500 Hz – 16 kHz ±45°

Maximum peak SPL

139 dB
Note: Measured with music, half-space loading, referred to 1 meter.

Dynamic range

>110 dB

Coverage

50° symmetrical

Acoustical crossover

1600 Hz
Note: At this frequency, the transducers produce equal sound pressure levels.

TRANSDUCERS
Low/low-mid frequency

Two high-power 12" cone drivers with neodymium magnets

Nominal impedance: 2

Voice coil size: 4"

Power handling capability: 1200 W (AES)
Note: Power handling is measured under AES standard conditions: transducers driven

continuously for two hours with band limited noise signal having a 6 dB peak-average ratio.

High frequency

4" compression driver

Nominal impedance: 8

Voice coil size: 4"

Diaphragm size: 4"

Exit size: 1.5"

Power handling capability: 250 W (AES)
Note: Power handling is measured under AES standard conditions: transducers driven

continuously for two hours with band limited noise signal having a 6 dB peak-average ratio.

APPENDIx b: mJf-212A SPECIfICATIONS AND DImENSIONAl DRAwINGS