beautypg.com

Fp2501 manual pilot flame, Dfx & dbx series vent free fireplaces, Fp2273 pilot bad flame – Monessen Hearth DFX24C User Manual

Page 20: Flame appearance, Check the pilot flame, Millivolt control, Manual & hi/lo control

background image

0

33D4047

DFX & DBX Series Vent Free Fireplaces

FP2501
manual pilot flame

FP2273
pilot bad flame

FP2272
pilot correct flame

FLAME APPEARANCE

Flames from the pilot, front and rear burner should be visually checked as soon as the
heater is installed.
In addition, periodically check the flames visually during operation.

CHECk THE PILOT FLAME

The pilot flame must always be present when the heater is in operation. It should just
touch the top of the thermocouple tip for natural. Refer to Figures 23 & 24 for correct pilot
flame.
If the pilot flame does not touch the thermocouple, then the main burner cannot function
reliably. Refer to Figures 23 & 24 for incorrect shape of pilot flame.

Figure 23 -
Millivolt Control Pilot Flame Appearance

Thermocouple
for Natural Gas

Thermocouple
for LP

FP7

Thermocouple
for Natural Gas

Thermocouple
for LP

FP73

MILLIVOLT CONTROL

Correct Pilot Flame Appearance

Incorrect Pilot Flame Appearance

MANUAL & HI/LO CONTROL

Thermocouple
for Natural Gas

Thermocouple
for LP

Thermocouple
for Natural Gas

Thermocouple
for LP

FP50

Correct Pilot Flame Appearance

Incorrect Pilot Flame Appearance

Figure 24 -
Manual & Hi/Lo Control Pilot Flame Appearance