2. routine maintenance – Miller Electric 400P User Manual
Page 48

OM-4421 Page 42
9-2. Routine Maintenance
!
Stop engine before maintaining.
.
See Engine Manual and Maintenance Label
for important start-up, service, and storage
information. Service engine more often if
used in severe conditions.
Recycle engine
fluids.
n = Check
Z = Change
~ = Clean
l = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
8
Hours
FUEL
WATER
n Fuel/Water Separator
n Fuel Level
n Oil Level
~ Oil, Fuel Spills
n Coolant Level
Every
50
Hours
~ Weld Terminals
Every
100
Hours
~ Battery Terminals
n Air Cleaner Hoses
n Air Cleaner Element
Every
250
Hours
1/2 in.
(13 mm)
Engine
Manual,
l Unreadable Labels
n Fan Belt Tension
Z Oil Z Oil Filter
n~Spark Arrestor
Every
500
Hours
nl Weld Cables
Every
1000
Hours
OR
SLUDGE
FUEL Section 9-7,
gine Manual
nRadiator Fluid Level And
Thermosstat
~ Inside Unit
Z FuelFilter
~ Drain Sludge
n~ Slip Rings*
nl Brushes*
nValve Clearance*
Every
2000
Hours
~ Injectors*