Usage Below Freezing

When the temperature is below freezing, the Inflatable PFD should
be worn partially inflated because a fully discharged cylinder may not
quickly or adequately inflate your Inflatable PFD. Under these conditions
use the oral inflator to adequately top-up the PFD, after CO2 inflation.
WARNING: CO2 inflation could over-pressurize and damage your

Inflatable PFD if already fully inflated.

Re-arming Your PFD (MD3075)

NOTE: A re-arm kit (MA7203) is required for this procedure.

IMPORTANT: Follow instructions in the exact sequence below.

1) Open bottom cover flap so that manual inflator is exposed (Fig. 7).
2) Remove the cylinder/bayonet assembly by rotating counterclockwise

and then pull out. Discard the used cylinder/bayonet assembly.

3) Check the new cylinder/bayonet assembly to ensure the o-ring is in

place and the sensor ring is attached (Fig. 7). Ensure that the CO2

cylinder has not been pierced (Fig. 7).

Inflatable PFD Owner’s Manual

6

Dust cap
position for
deflation

Dust cap
in stowed
position

Oral Inflator

FIGURE 6

Cap In

Deflate

Position

FIGURE 5