Troubleshooting torch, 7. troubleshooting torch – Miller Electric ICE-100T User Manual
Page 47

.
A complete Parts List is available at www.MillerWelds.com
OM-201 872 Page 43
7-7.
Troubleshooting Torch
Trouble
Remedy
Arc goes on and off while cutting.
Torch travel speed too slow; increase travel speed (see Section 5-5). Clean or replace torch consumables
as necessary (see Section 7-4). Be sure work clamp is securely attached to workpiece.
Arc goes out while cutting.
Be sure work clamp is securely attached to workpiece. Make sure tip is on or near [1/16 in (1.6 mm) to
1/8 in (3.2 mm)] workpiece (see Section 5-5). Clean or replace torch consumables as necessary (see
Section 7-4).
Sparks come out top of cut or cut is not
clean.
Torch travel speed too fast; reduce travel speed (see Section 5-5). Clean or replace torch consumables
as necessary (see Section 7-4). Be sure work clamp is securely attached to workpiece. Unit not capable
of cutting metals thicker than rating (see Section 4-3).
Trouble lights are on; unit has no cutting
output.
Check torch consumables. Check for gas/air flow at torch. Check air supply connection and pressure to
unit and torch. Reset unit Power switch. Have Factory Authorized Service Agent check torch and
connections inside unit.