beautypg.com

Dry-running sensor hydrostop – Metabo Dry-running Sensor Hydrostop User Manual

Page 8

background image

Hydrostop

2.1

Dry-running sensor Hydrostop

Read instructions carefully before operating this device. Keep instructions for
future reference.

Safety first!

Electricity and water are a dangerous combination! A current-carrying cable or
electrical appliance in water can lead to a lethal electric shock, as soon as
somebody touches the water. It is therefore absolutely necessary that you
observe the following safety information:

The dry-running sensor’s outer parts (plug, cable
and sensor enclosure) must not come in contact
with water. Position the dry-running sensor so that

no parts can fall into water;
no water can run over any of the parts when

the pump starts;

no parts can become moist by atmospheric

influence;

any possibly used extension cables do not

come in contact with water either.

Connect the dry-running sensor only to a power source meeting the following requi-
rements:

Power supply cables and extension cables with a minimum conductor cross sec-

tion of 1.0 mm required by VDE for rubber-sheathed cable type H07 RNF.

When pumping from swimming pool or garden pond, the pump must be protected

by a residual current device according to VDE 0100, parts 702 and 738.

Check dry-running sensor for any damage before use. Do not use a damaged
device; it cannot be repaired, as the device will no longer be waterproof. Damaged
cables in particular must not be repaired. If the dry-running sensor is faulty, replace
with an intact one.

Drain dry-running sensor completely if there is risk of freezing.

XT0001E1.fm

2Great Britain