Electrical Service Guide
340
440
Input Voltage
230
400
520
230
400
520
Input Amperes at Rated Output
55
32
25
79
46
25
Max Recommended Standard Fuse or Circuit
Breaker Rating in Amperes
55
32
25
79
46
25
** Input Conductor Size in mm
2
6
6
6
6
6
6
** Grounding Conductor Size in mm
2
6
6
6
6
6
6
** Power cord supplied with the unit is sized for 230V operation. Larger power cord may be required for cable lengths greater than 3 meters. C
onsult national and local regulations.
2-6.
Selecting a Location and Connecting Input Power
Have only qualified persons make
this installation.
1
Rating Label
Supply correct input power.
ST-801 721
18 in (457 mm)
for airflow
1
1.6
220
2
2.5
5
4
100
30
60
160
Amp.
ON
OFF
L1 (U)
L2 (V)
L3 (W)
GND/PE
Connect First
GND/PE