– If the exhaust is ducted into an

inactive flue, the air must be expelled
parallel to the flow direction of the
flue.

Never connect an exhaust hood to
an active chimney, dryer vent, flue,
or room venting ductwork. Seek
professional advice before
connecting an exhaust hood vent to
an existing, inactive chimney or vent
flue.

Important

If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.

Condensate trap

optional accessory

In some cases, a condensate trap may
also be required to collect and
evaporate any condensate which may
occur. This optional accessory is
available for ducts 5" (125 mm) and
5

7

/

8

" (150 mm) in diameter.

^ When installing a condensate trap,

ensure that it is positioned vertically
and if possible directly above the
exhaust outlet.