CLEARANCES and HEIGHT REQUIREMENTS

5.

Mantel clearances The canopy supplied with
the unit must be installed.
If a combustible mantel
is installed, it must meet the clearance requirements
detailed in Figure 6.

6.

Floor clearance — This fi rebox hearth opening
(inter-chamber fl oor) must be installed
at least

1

/

2

" above any combustible

fl ooring material or, the fi rebox hearth
may be installed fl ush with the fl oor
if noncombustible material such as
slate or marble is installed between
the base of the fi rebox and the com-
bustible fl ooring.

The firebox may be

installed directly on a combustible
floor or raised on a platform of an
appropriate height. Do not place fire-
box on carpeting, vinyl, or other soft
floor coverings. It may, however, be
placed on a flat wood, plywood, par-
ticle board, or other hard surfaces. Be
sure firebox rests on a solid continuous floor or platform with
appropriate framing for support so that no cold air can enter room
from under the firebox. Refer to Figure 8.

NOTE: The combustible area above the facing must
not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.

Figure 6c - Minimum Mantel Clearances

Figure 6 a&b - Minimum Mantel Clearances for Canopy

and Wide Profi le Canopy

Figure 7 - Floor Clearance above Combustible

Flooring Material

Figure 8 - Floor Clearance above Noncombustible

Flooring Material

Canopy

Wide Profi le

Canopy

Combustible Material

Noncombustible

Material