Operation 10, Turning on the fan 10, Selecting the power level 10 – Miele DA 250 User Manual
Page 10: Delayed shut down 10, Operation, Turning on the fan, Selecting the power level, Delayed shut down
Turning on the fan
^ Press the On/Off button.
The fan runs at power level “lI”. The
On/Off indicator lights.
Selecting the power level
^ Use the _ buttons to select the
desired power level.
& = increases the fan speed
$ = decreases the fan speed
Level "1" to "3" (green indicators) are
usually sufficient for normal cooking.
Intensive setting
Level "4" (yellow indicator) should be
used for a short period when frying or
cooking food with a strong aroma.
Fan performance
The maximum air flow capacity is
625 cfm. Factors such as narrow duct
diameter and bends will affect this
value.
Level 1 operates at 40% capacity
Level 2 operates at 60% capacity
Level 3 operates at 80% capacity
Level 4 operates at 100% capacity
Delayed Shut Down
If odors or smoke remain in the kitchen
after cooking has been completed, the
Delayed Shut Down feature can be
selected to allow the hood to continue
running for either 5 or 15 minutes.
^ Press the Delayed Shut Down button
while the fan is still running:
Press once = 5 minutes delay
(left indicator lights)
Press twice = 15 minute delay
(right indicator lights)
To cancel the Delayed Shut Down
feature press the button again.
Operation
10