DEFINITIONS FOR ILLUMINATED LED INDICATORS

Power

ON

Site

Wiring

Fault

Circuit

Breaker

Alarm

CONDITION

On Off Set Off


Normal Mode

Off On/Off Set

Two

Beeps


Utility Failure-
the UPS is in the battery
mode.

Off On/Off Set

Rapid

Beeps


Utility Failure-
The UPS is in the battery
mode and will run out of battery-power shortly.

Off Off Up

Two

Beeps

or

Rapid

Beeps


System Overload-
Occurs when connected
equipment exceeds the rating of UPS. Turn
the UPS off, unplug at least one piece of
equipment, wait 10-seconds, reset the circuit
breaker and turn the UPS on.

Off On/Off Set

Long
Beep


Battery Overload-
Occurs when connected
equipment exceeds the rating of battery-
powered outlets of the UPS. Turn the UPS off,
unplug at least one piece of equipment from
battery-powered outlets, wait 10-seconds,
reset the circuit breaker and turn the UPS on.

On/Off On Set None


Site Wiring Fault (MN 525 Only)-
This indi-
cates a wiring problem with the AC wall outlet
such as bad ground, missing ground, or re-
versed wiring. Disconnect all electrical equip-
ment from the UPS’s outlets and have an
electrician check the AC wall outlet to ensure
proper wiring.