Ssc200 user’s manual – Maretron SSC200 User Manual
Page 30

SSC200 User’s Manual
Page A4
Appendix A – NMEA 0183 Interfacing
Revision 1.8
$PMAREXE,SSC200,,5D,2,,,
other variation sources (i.e., NMEA 2000
®
interface and manual entries).
$PMAREXE,SSC200,,5D,3,,,
from either the NMEA 0183 interface or the NMEA 2000
®
interface.
$PMAREXE,SSC200,,5E,2,”damping period”,,
programmed in “damping period”. The damping period is programmable from 100 to 60000, which
represents 100ms to 60 seconds.
$PMAREXE,SSC200,,5E,11,,,
value used, along with the current operating temperature of the compass. The boat must remain at rest
for a period of one minute after this command is issued.
$PMAREXE,SSC200,,5E,12,,,
$PMAREXE,SSC200,,50,,,,
PMARSETPX – Maretron Proprietary Set Period Sentence
The SSC200 can be programmed to enable or disable the periodic transmission of the HDG, HDM,
HDT, ROT, and PMAROUT sentences. In addition, the periodic transmission rate for these sentences
and the Variation Lifetime (see RMC and VTG) can be programmed using this sentence.
$PMARSETPX,SSC200,,A,B*hh
B: Integer where “0” disables sentence and positive numbers are multipliers of 1ms (i.e.,
programmed integer of 200 would mean a 200ms transmission interval)
Identifier Code
Sentence
Default Rate
00 HDG
100
(100ms)
01
HDM
0 or Disabled
02
HDT
0 or Disabled
03
ROT
200 or 200ms
04
PMAROUT
1000 or 1sec
0A
Variation Lifetime
5000 or 5sec
Some example sentences are shown below:
1. To disable transmission of the HDG sentence:
$PMARSETPX,SSC200,,00,0
2. To enable transmission of the HDG sentence at intervals of 100 ms:
$PMARSETPX,SSC200,,00,100
3. To disable transmission of the HDM sentence:
$PMARSETPX,SSC200,,01,0
4. To enable transmission of the HDM sentence at intervals of 1000 ms:
$PMARSETPX,SSC200,,01,1000