beautypg.com

Tac/taf series, Foodservice solid door reach-ins, Plan view side view elevation view – Master Bilt TAF-27HDSA User Manual

Page 2

background image

NOTE: Cabinet designed for optimum performance in air-conditioned area at 75°F ambient and 55% relative humidity.

All specifications subject to change without notice.

908 Highway 15 North • New Albany, MS 38652
PHONE: 800-647-1284 or 662-534-9061 • FAX: 800-232-3966 or 662-534-6049 • www.master-bilt.com

PLAN VIEW

SIDE VIEW

ELEVATION VIEW

��������������������

��������������������

��������������������

TAC/TAF SERIES

FOODSERVICE SOLID DOOR REACH-INS

TECHNICAL SPECIFICATIONS

LISTINGS

HOOKUP

BID SPECIFICATIONS

Item no. TAC-_____HDSA and/or Item no.
TAF-_____HDSA.

Provide_______( ) Medium Temp

Foodservice Solid Door Reach-in(s), and/or
_______( ) Low Temp Foodservice Solid
Door Reach-In(s). Master-Bilt model no(s).
TAC-_____HDSA and/or TAF_____HDSA.

Cabinet to be constructed of stainless steel

interior and exterior. TAF models will be
equipped with an electronically controlled

1197-7/09-web

©Master-Bilt Products division of Standex International, Inc. All rights reserved. Printed in U.S.A.

TAC MODELS: Via plug in, 8 foot long, flexible 3 wire 14/3 cord

with molded plug. 20 amp service is required for all models.

TAF-27HDSA: Via plug in, 8 foot long, flexible 3 wire 14/3 cord with

molded plug. 15 amp service is recommended.

TAF-48HDSA: Hardwired
TAF-74HDSA: Hardwired with separate junction boxes for 115V and

208- 230V and with a maximum 20 amp fuse.

monitoring system as well as an automatic
defrost with double failsafe override.

All models to have digital thermometer

(built into electronic controller interface on
TAF models), electric condensate evaporator,
heavy-duty casters, three welded wire, gray
epoxy-coated shelves per section. Doors will
be self-closing with 90° hold-open feature,
locking horizontal handles and door frame
heater.

The refrigeration system will be top

mounted and self-contained using R-134a
refrigerant in TAC models and R-404A in TAF
models. The temperature range will be 34°
to 41°F (1° to 5°C) for TAC models and 0° to
-20°F (-18° to -29°C) for TAF models.

Cabinet to have standard limited 4 year

extended compressor warranty and 1 year
limited parts and labor warranty. Cabinet to
be UL, C-UL and NSF listed.

NEMA 5-20P
(TAC MODELS
& TAF-27HDSA)

MODEL

DIMENSIONS

(in.)

DIMENSIONS

(mm)

VOLTS**

AMPS

UNIT

H.P.

NO. OF

DOORS

NO. OF

SHELVES

STANDARD
SHELF SIZE

(in inches)

CAP.

CU.

FT.

SHIP

CU.

FT.

SHIP

WT.

LB/KG

L

D

H*

L

D

H*

MEDIUM TEMP
TAC-27HDSA

31

35

3

/

4

80

1

/

2

787

908 2045

115

12.1

1/2

1

3

25

1

/

4

x 26

25.4

76.0 355/161

TAC-48HDSA

52

35

3

/

4

80

1

/

2

1321 908 2045

115

13.1

1/2

2

6

22

1

/

2

x 26

45.9 119.0 465/211

TAC-74HDSA

78

35

3

/

4

80

1

/

2

1981 908 2045

115

15.0

3/4

3

9

22

1

/

2

x 26

71.4 174.0 650/295

LOW TEMP
TAF-27HDSA

31

35

3

/

4

80

1

/

2

787

908 2045

115

10.5

3/4

1

3

25

1

/

4

x 26

25.4

76.0 385/175

TAF-48HDSA

52

35

3

/

4

80

1

/

2

1321 908 2045 115/208-230

5.0/7.5

1

2

6

22

1

/

2

x 26

45.9 119.0 540/245

TAF-74HDSA

78

35

3

/

4

80

1

/

2

1981 908 2045 115/208-230 6.2/11.2 1

1

/

2

3

9

22

1

/

2

x 26

71.4 174.0 670/305

*Height includes casters. **TAF-48HDSA and TAF-74HDSA operate on a minimum of 208 volts. A voltage boosting transformer (part no. 39-01087)
must be used when the supply voltage is less than 208 volts.