beautypg.com

Qmvm series, Recommended operating conditions – Master Bilt QMVM-72 User Manual

Page 2

background image

908 Highway 15 North • New Albany, MS 38652
PHONE: 800-647-1284 or 662-534-9061 • FAX: 800-232-3966 or 662-534-6049 • www.master-bilt.com

QMVM SERIES

QUANTUM SERIES MEDIUM TEMP VERTICAL

OPEN DISPLAY MERCHANDISERS

TECHNICAL SPECIFICATIONS

LISTINGS

HOOKUP

BID SPECIFICATIONS

Item no. QMVM-_______________
Provide_________( ) Quantum Series
Medium Temp Vertical Open Display
Merchandiser(s), Master-Bilt model no.
QMVM-__________.

Merchandiser to be constructed of 24

gauge painted textured galvanized steel
interior and exterior and will be equipped
with an electronically controlled monitor-

324-3/11-web

©Master-Bilt Products division of Standex International, Inc. All rights reserved. Printed in U.S.A.

Electrical: QMVM-36E and QMVM-48E via plug in, 9 foot long
flexible four wire 208-230v 14/4 cord with neutral and ground
wires and molded plug. QMVM-72E is a hardwire.
Plumbing: Requires connection to customer’s drain

PLAN VIEW

ELEVATION VIEW

ing system.

Other features include adjustable two-

position shelves, independent shelf light-
ing, perforated interior back wall, electric
defrost and 2" foamed-in-place “zero ODP”
urethane insulation.

The refrigeration system to be self-con-

tained, have a front condenser air intake
and rear air discharge and use R-404A refrig-

erant. The temperature range will be 34° to
41°F (1° to 5°C).

Merchandiser to have standard limited

three year extended compressor warranty
and two year limited parts and labor war-
ranty.

Merchandiser to be UL and C-UL listed

and UL EPH classified.

MODEL

DIMENSIONS

(in.)

DIMENSIONS

(mm)

VOLTS

AMPS*

UNIT

H.P.

NO. OF

SHELVES

STANDARD

SHELF

WIDTH

(in inches)

CAP.

CU.

FT.

SHIP

CU.

FT.

SHIP

WT.

LB/KG

L

D

H

L

D

H

QMVM-36E

36

30

81

914

762 2057

208-230

13.5

1

3

14 x 31

1

/

8

13.6

89.0

525/239

QMVM-48E

48

30

81

1219 762 2057

208-230

16.1

1

3

14 x 43

1

/

8

20.4

107.0

640/291

QMVM-72E

72

30

81

1829 762 2057 115/208-230 3.7/13.7

1

1

/

2

6

14 x 33

1

/

16

31.5

152.0

860/391

*If condensate evaporator pan accessory is used,
it must be field installed and requires a dedicated
15 amp, 120 volt circuit.
Note: 208-230/60/1 also requires neutral
and safety ground wire.

SIDE VIEW

RECOMMENDED OPERATING CONDITIONS

All specifications subject to change without notice.

• Merchandisers designed to hold product

in the 34° to 41°F (1° to 5°C) range

• Designed to operate in air-conditioned

stores where the maximum temperature is
75°F and the maximum relative humidity
is 55%

• Should not be installed in direct sunlight

• Should not be installed near HVAC vents,

fans or doorways that will disrupt airflow
and compromise the function of the air
screen inside the case

• Bottom shelf should not be loaded such

that the front air intake is obstructed

• Floor drain should be properly trapped

• Factory installed controls should not be

altered, removed or replaced without
consent of the factory

• Product must not be displayed in the cold

air curtain

NEMA L14-20P
(QMVM-36E & QMVM-48E)

This manual is related to the following products: