OM-4417 Page 23

6-4. Description Of Controls (DX Models) (See Section 6-3)

1

Engine Switch

Use switch to control ignition circuit. Turn

switch to Start position for electric start. Turn

switch to On position to start engine using

starter handle (recoil). Turn switch to Off posi-

tion to stop engine.
2

Low Oil Level Light

Light goes on and engine stops if engine oil

level is too low.
Engine cannot be restarted until sufficient oil

is added.

!

Stop engine and add oil if light goes on

(see Section 5-4).

3

Starter Handle

Use starter handle to start unit if electric start

does not work.
4

Choke Control

Use control to change engine air/fuel mix.

Move control to far right if starting a cold en-

gine. Move control to far left if starting a warm

engine.
The engine starts at weld/power speed and

runs at weld/power speed under weld or gen-

erator power load. The engine returns to idle

speed 12 seconds after start-up or after weld

or generator power load is removed.

To Start:

D Open fuel valve (see Section 5-4).
D Set choke.
D Electric-Start: Turn Engine switch to

Start position.

Recoil: Turn Engine switch to On posi-

tion. Pull starter handle until engine

starts.

D Open choke as engine warms.

!

If the engine does not start, let engine
come to a complete stop before at-

tempting restart.

To Stop:

D Turn Engine switch to Off.

.

Always close fuel valve after stopping
unit. Moving unit with fuel valve open may

cause carburetor flooding and make

starting difficult.

5

Welding Range Table

Use table to determine correct weld amper-

age based on electrode size, type, and mate-

rial thickness.

6

Run / Idle Switch

Use switch to select whether the engine stays

at run speed continuously or whether the auto

idle feature is enabled so engine speed re-

turns to idle speed after start−up or after weld

or generator load is removed.
7

Weld Output Control

.

Set control at maximum for full generator
power output at AC receptacles.

Use control to select weld amperage. Control

may be adjusted while welding.
To Set Weld Output Control: Use table to

determine correct size electrode for weld am-

perage. Select electrode type and set control

to corresponding amperage range on name-

plate. Adjust control to obtain desired weld

performance.
EXAMPLE:
Electrode Diameter: 1/8
Electrode Type: E-6013
Current Control Setting: 90 − 120 A
8

Hourmeter

Use hourmeter to help schedule routine main-

tenance.